THERMOSALD ISC – MAINTENANCE & OPERATIONS MANUAL Rev. 2010 / 03
(Includes all previous models)
Manuale cod.: 3ES080x_V5.1_MU_EN Page Nr. 23 Tot. Nr . 47
4 START UP
4.1 - START UP PROCEDURES – INSPECTING THE SYSTEM AND THE PARTS USED
Stage 1 – In order to properly set up the system, read the instructions given in paragraph 4.8 THEORETIC
CALCULATIONS AND DIAGNOSTIC PROCEDURES and 4.9 SETUP PROCEDURES WITH THE AID OF
THE MULTI-LINGUAL CONTROL PANEL
Stage 2 – Use a Low Voltage Unit for power transformer outputs up to 10 Volt
Use a Standard Unit power transformer outputs from 11 to 99 V.
Use a High Voltage Unit for power transformer outputs from 100 to 140 V.
Use Primary mode for pulsed currents more than 220Amps.
Stage 3 – Make the system contructed in an workmanshiplike manner.
Stage 3.1 – Use sealing bands supplied by our Company or equivalent (don’t use NI-CR sealing bands).
Stage 3.2 – The power cable inside the T.A. must not turn around T.A (only 1 single line inside).
Stage 4 – For any further information, call 3E – ENGINEERING DEPARTMENT.
TECHNICAL NOTES
From software V5.1 it’s possible modify the temperature coefficient of the sealing bands in part per milion PPM; modifying
the PPM also other parameters will change in automatic as shown in the following table; for compatibility with the previous
models the thermoregulator outputs from our factory with the default temperature coefficient PPM=1465 that maintain the
heating characteristic and the voltage of the analog input unchanged.
TABLE OF PARAMETERS DEPENDING ON TEMPERATURE COEFFICIENT
Master Reset
PPM= 1465 1300 1100 1000 913 750
BIT/°C= 1465:488=3 1300:488=2.6 1100:488=2.2 1000:488=2.0 913:488=1.8 750:488=1.5
T.MAX[°C]= 300 1000:2.6=384 1000:2.2=454 1000:2.0=500 1000:1.8=555 1000:1.5=666
IN. ANALOG.[ mv/°C] 4V/300=13.33 4V/384=10.42 4V/454=8.81 4V/500=8.00 4V/555=7.21 4V/666=6.00
POT.(°C/GIRO) 300/10=30 384/10=38.4 454/10=45.4 500/10=50 555/10=55.5 666/10=66.6
NOTE: 488, 1000, 4V, 10 are constants