THERMOSALD ISC – MAINTENANCE & OPERATIONS MANUAL Rev. 2010 / 03
(Includes all previous models)
Manuale cod.: 3ES080x_V5.1_MU_EN Page Nr. 4 Tot. Nr . 47
0.2. COMPLIANCE WITH ELECTRO-MAGNETIC STANDARDS – CE KITE MARKS
TESTS AND RESULTS:
Test conditions:
•
••
• Mains supply filter Mod. Siemens B84112-B-B60 ( 115 / 250 V - 6A - 50/60 Hz )
•
••
• Connecting cable thermoregulator-panel mt.5
•
••
• Input power cables length mt. 5
• Output power cables length mt.5
Normative References:
• CEI EN 50081-2 (06/1997) Electromagnetic compatibility – Generic emission standard - Part 2 - industrial
environment.
• CEI EN 61000-6-2 (02/2000) Electromagnetic compatibility - Generic immunity standard - industrial environment.
EMISSION Requisites
Test Normative References Test Result
• Electromagnetic Emission CEI EN 55011 S
IMMUNITY Requisites
• Immunity elecricity static discharge (ESD) CEI IEC 1000-4-2 S
• Immunity radiated electromagnetic field (AM) EN 61000-4-3 S
• Immunity fast transient oscillation (BURST) CEI IEC 1000-4-4 S
• Immunity high energy pulse (SURGE) CEI EN61000-4-5 S
• Immunity conduit RF CEI EN61000-4-6 S
• Immunity electromagnetic field 50Hz CEI EN61000-4-8 S
• Immunity micro interruption of main CEI EN61000-4-11 S
S=Prova Superata
THE PRODUCT IS COMPLIANCE TO ABOVE MENTIONED NORMES EMC in accord to DIRECTIVE
89/336/CEE and DLg N.476/92 e N.615/96
(EMC Test Report n. 029-03-RP on 03/02/03) .
THE PRODUCT IS COMPLIANCE TO LOW VOLTAGE NORME in accord to DIRECTIVE 73/23/CEE,
93/68CEE.