THERMOSALD ISC – MAINTENANCE & OPERATIONS MANUAL Rev. 2010 / 03
(Includes all previous models)
Manuale cod.: 3ES080x_V5.1_MU_EN Page Nr. 31 Tot. Nr . 47
5 MAINTENANCE
5.1 – CHANGING THE SEALING BANDS WITH MACHINE COLD ( i.e. gripper jaws at ambient temperature )
HAVE YOU TO CHANGE THE SEALING BANDS WITH THE MACHINE AT AMBIENT TEMPERATURE,
BECAUSE OF A PROGRAMMED MAINTENANCE?
Pre-heat and seal comands are off; the machine is at ambient temperature; The sealing bands have little differences in
measure; for optimum accuracy it is possible to do an automatic cold balance to compensate the differences; it is possible
doing a burn-in cycle after, to become stable electric characteristics.
1 – Switch off power, release pre-heat and seal commands, let the gripper jaws getting cold down.
2 – Install the new sealing bands, switch on power.
3 – Make the CALIBRATING
Normally is not necessary change ambient temperature (gripper jaws temperature) in the SETTING DATA and doing a burn
in cycle at the end of calibrating.
4 - THE MACHINE IS READY TO WORK.