EasyManuals Logo

3M 600 Series Datasheet

3M 600 Series
4 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #2 background imageLoading...
Page #2 background image
A combination of gas / vapour and particulate filters - The
5911 / 5925 / 5935 particulate filters can be used with 6000
S
eries gas / vapour filters using retainer 501.
Note: the 6098 or 6099 filters should not be used with the
6000 Series half masks.
Supplied-air mode using the 3M S-200 Respirator System
(For information on the Supplied-Air System and applications
please see the 3M S-200 Data Sheet).
Approvals
T
he 3M 6000 Series half masks and 6000/5000/2000 Series
filters have been shown to meet the Basic Safety Requirements
under Article 10 and 11 B of the European Community Directive
89/686, and are thus CE-marked.
Approval body for the facepieces:
DANTEST identification number 0200
Body involved in Quality Assurance Assessment:
BSI/UL identification number 0086
Materials
Facepiece - Thermoplastic Elastomer
Head Harness - Polyester / Cotton Elastic
Inhale Valve - Natural Rubber
Exhale Valve - Silicone Rubber
Gasket - Silicone Rubber
Filter Body (6000) - Polystyrene
Filter Element (6000) - Activated/Treated Carbon
Filter Material (5911 / - Polypropylene
5925 / 5935 and 2000
Series)
Maximum Product Weight:
- With filters 355 grams
- Without filters 85 grams
Standards
These products have been tested to the relevant European Standards as
shown below:
Facepiece EN140:1998 (6100, 6200, 6300)
Filter EN141:2000 (6054, 6057, 6059,
6075 & 6096)
EN14387:2004 (6051, 6055)
EN 143:2000 (2125, 2128, 2135,
2138, 5911, 5925, 5935, 6035,
6038)
Correct Usage
The 6000 Series facepieces when fitted with 6000 Series
gas/vapour filters may be used in concentrations of gases or
vapours (types specified by 3M) up to 10 times WEL or 1000 ppm
(
5000 ppm for 6055) whichever value is lower (APF = 10)*.
Gas/vapour filters should not be used to protect the wearer
against a gas or vapour that has poor warning properties (smell
or taste).
The 6000 Series facepieces when used in conjunction with the
5911 filter may be used in concentrations of solid and aqueous
aerosols up to 4 times WEL (APF = 4)*.
The 6000 Series facepieces when used in conjunction
with the 5925, 2125, or 2128 filters may be used in
concentrations of particulates up to 10 times WEL
(APF = 10)*.
The 6000 Series facepieces when used in conjunction
with the 5935, 2135, 6038, 6035, or 2138 may be used in
concentrations of particulates up to 20 times WEL
(APF = 20)*.
The 6000 Series facepieces when used in conjunction with the
2128 and 2138 may be used to protect against ozone up to 10
times WEL (APF = 10)* and offer relief from nuisance odours
below the WEL.
The 6000 Series facepieces when used in conjunction with the
2128 and 2138 may be used to offer relief from acid gases
below the WEL.
The 6000 Series facepieces when used with the 6038 filter
may be used to protect against Hydrogen Fluoride gas up to
30ppm and offer relief from Ozone, Organic Vapours and acid
gases below WEL.
*WEL - Workplace Exposure Limit.
Cleaning and Storage
1. Cleaning is recommended after each use. Remove the
gas/vapour and/or particulate filters.
2. Clean the facepiece (excluding filters) with 3M 105 face seal
cleaners or by immersing in warm cleaning solution, water
temperature not to exceed 50°C and scrub with soft brush until
clean. Add neutral detergent if necessary.
Do not use cleaners containing lanolin or other oils.
3. Rinse in fresh, warm water and air dry in a non- contaminated
atmosphere.
4. Respirator components, especially exhalation valve and seat,
should be inspected prior to each use. A respirator with any
damaged or deteriorated components should be discarded.
5. The cleaned respirator should be stored away from
contaminated areas when not in use.

Other manuals for 3M 600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the 3M 600 Series and is the answer not in the manual?

3M 600 Series Specifications

General IconGeneral
Operating Temperature-10°C to +50°C
TypeMotion Sensor
MountingWall Mount
ApplicationIndoor
Detection Angle110 degrees
Power Supply12V DC
Output TypeRelay Contact
Housing MaterialPlastic