Quick Start Guide
3M
™
Half Facepiece Reusable Respirators 6100 (Sm)/6200 (Med)/6300 (Lg) and particulate lter
assembly including: 3M
™
N95 Particulate Filter 5N11, 3M
™
Filter Retainer 501 and
3M
™
Filter Adapter 603. Optional 3M
™
Exhalation Valve Filter 604.
Notes:
• Before using these respirator systems, all users must read and understand the product User Instructions.
• Do not use with beards or other facial hair or other conditions that prevent a good seal between the face and
the faceseal of the respirator.
• Perform hand hygiene and use other applicable PPE as determined by your facility and/or infection control
policy.
Step 1: Inspection
Inspect all components according to the product User Instructions prior to each use. Check for cracks,
tears, holes, deformation or missing components.
Step 2: Filter assembly
1. Place the lter pad in the
lter retainer (501) with
the lter print facing up.
2. Snap the lter
adapter (603) into the
lter retainer (501).
3. Ensure the lter seal is free from creases and gaps and
print is oriented correctly.
6100/6200/6300 603 (x2) 5N11 (x2) 501 (x2)
April 2021
604 (Optional)
1. Ensure the valve
cover of the 6000
Series facepiece is
clean, uncontaminat-
ed and undamaged.
The valve cover is
on the front of the
respirator and has a
large 3M logo. There
are four breathing
slots surrounding the
logo.
2. Align the connector
tabs and hooks on the
back of the EVF with
the breathing slots of
the valve cover.
Tip: Installing the
EVF with either hook
at the top position
may help with proper
alignment of the EVF.
3. Press the EVF
onto the valve
cover. The EVF
should sit evenly on
the valve
cover.
4. If the EVF is not
seated evenly on
the valve cover, as
shown above, in
Fig. 4, repeat steps
2 & 3.
5. Slowly rotate the
EVF clockwise until
rotation stops. Pull
outward lightly on
the EVF to con rm
a complete
connection.
Step 3 (optional): EVF Connection to Facepiece