EasyManua.ls Logo

3M 6204 - Connecting the Power

3M 6204
33 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1
2
3 4 5 6 7
Reader Equipment Installation
8
3
M Toll RFID Reader 6204
Quick Start Guide
2.2.5. Connecting the Power
The 6204 operates on 24 Vdc provided through the bulkhead connector on
the rear of the reader.
The bulkhead power connections are as follows. Note that both pairs must
be connected.
Pair Pin Color Pin Name Function
9 T Red +24 VDC Power
U Green 24 VDC GND Ground
16 h Yellow +24 VDC Heater Power
j Green 24 VDC GND Heater Ground
Connect the power supply to the reader cable as shown and connect the
power supply to your 100–240 Vac, 50-60 Hz power source. Allow 30
seconds for the reader to initialize.
Refer to the Section 6.1.8 for details on the bulkhead connector.