PART Typically replaced Comment
A Filter cover If damaged To Hold and protect the lters
B Spark arrestor When needed
Replace deformed or damaged to
protect the particle lter from sparks
and spatter
C Pre-lter
When needed, at least
weekly.
Regular replacement of the prelter
extends the life of the particle lter,
saving money while also increasing the
battery run-time
D Particle lter
When needed, at least
every month
Replace when particle lter indicator
becomes red. Otherwise, replace
whenever the battery operating time
becomes too short, or when the low
airow alarm is triggered by a fully
loaded lter.
E Gas lter
According to
predetermined
employer change-out
schedule
Smell and taste is not recommended
as a measure for determining when to
change gas lters.
F Odour lter
Change when
unpleas ant smell occur
Odour lter is not neccessary when a
gas and vapour lter is used
G Ado Battery When needed
Replace if the battery is no longer
taking charge to an acceptable level
H Battery charger If damaged Replace if any parts are damaged
I Breathing tube
If damaged or
contaminated
Use a breathing tube cover to extend
the life time or a rubber breathing tube
for use in heavy duty environments
Replacement table 3M
Ado
Powered Air Purifying Respirator
What is listed above are basic needs. For detailed instructions and guidance, always follow the user instruction.