T-D2-IN / T-D2-OS Service Manual
Ver. 1.00
42
Error Code
Malfunction description Cancellation method
391
the power or water supply
Diagnosis Checkpoint
1 AFR rod fault (Refer to section 10-6)
ection: connection/breakage of wires, soot on it.
I
Error Code
Malfunction description Cancellation method
441
Flow sensor failure (Only Easy
the power or water supply
Diagnosis Checkpoint
1 Flow sensor failure (Refer to section 10-9)
Visual inspection: connection/breakage of wires and/or debris on impeller.
Check voltage/resistance between (red & black) or (white & black)
H2
Error Code
Malfunction description Cancellation method
510
Fault of driving circuit for main gas solenoid
Turn off the power supply
(The computer checks the condition of the main
gas valve immediately after every operation and
the conditions of the solenoid valves 6 hours
Diagnosis Checkpoint
1 PCB and/or main gas valve fault
(Refer to section 10-4 & 10-15)
Visual inspection of gas valves: connection/breakage of wires.
Normal: 78 to 100 VDC between COM (blue) & #3 (light blue)
(during operation)
Normal: 78 to 100 VDC between COM (blue) & #9 (green)
(during operation)
Normal: 78 to 100 VDC between COM (blue) & #53 (orange)
(during operation)
Normal: 78 to 100 VDC between COM (blue) & #73 (red)
(during operation)
Visual inspection of PCB: connection/breakage of wires and/or burn marks
on the computer board.
2 Gas solenoid valve fault (MV,