―2―
Following symbols are used on the instrument and in the instruction
manual. Attention should be paid to each symbol to ensure your safety.
Refer to the instructions in the manual.
This symbol is marked where the user must refer to the
instruction manual so as not to cause personal injury or
instrument damage.
Indicates an instrument with double or reinforced insulation.
Indicates that this instrument can clamp on bare conductors
when measuring a voltage corresponding to the applicable
Measurement category, which is marked next to this symbol.
Indicates AC (Alternating Current).
Indicates DC (Direct Current).
Indicates AC and DC.
DANGER
Never make measurement on a circuit above 750VAC or 1000VDC.
Do not attempt to make measurement in the presence of flammable
gasses, fumes, vapor or dust. Otherwise, the use of the instrument
may cause sparking, which can lead to an explosion.
Transformer jaw tips are designed not to short the circuit under
test. If equipment under test has exposed conductive parts,
however, extra precaution should be taken to minimize the
possibility of shorting.
Never attempt to use the instrument if its surface or your hand is wet.
Do not exceed the maximum allowable input of any measurement
range.
Never open the battery compartment cover when making measurement.
Never try to make measurement if any abnormal conditions, such
as broken Transformer jaws or case is noted.
The instrument is to be used only in its intended applications or
conditions. Otherwise, safety functions equipped with the
instrument doesn
,
t work, and instrument damage or serious
personal injury may be caused.
WARNING
Never attempt to make any measurement, if the instrument has any
structural abnormality such as cracked case and exposed metal part.
Do not turn the function selector switch with test leads connected to
the instrument.
Do not install substitute parts or make any modification to the
instrument. Return the instrument to your distributor for repair or re-
calibration.
Do not try to replace the batteries if the surface of the instrument is wet.
Always switch off the instrument before opening the battery
compartment cover for battery replacement.

Questions and Answers: