Software options Ordering no #3 Notes and rules
No option X00
1)
Restricted earth fault protection, low impedance 1MRK004001-AA A01
2)
High impedance differential protection - 3 blocks 1MRK004001-AB A02
3)
Transformer differential protection - 2 winding 1MRK004001-AP A31
4)
Transformer differential protection - 2 and 3 winding 1MRK004001-AR A33
5)
Out-of-step protection 1MRK004001-BW B22
Rotor Fault Detection by Injection 1MRK004001-BV B31
Stator Fault Detection by Injection 1MRK004001-BX B32
Sensitive directional residual overcurrent and power protection 1MRK004001-CT C16
Voltage restrained overcurrent protection 1MRK004001-UN C36
Rotor overload protection 1MRK004001-UR C38
Four step directional negative phase sequence overcurrent protection - 1 block 1MRK004001-UH C41
6)
Four step directional negative phase sequence overcurrent protection - 2 blocks 1MRK004001-UK C42
7)
Average power transient earth fault protection 1MRK004001-UY C54
100% Stator E/F 3rd harmonic 1MRK004001-DE D21
8)
Frequency time accumulation protection 1MRK004001-EC E03
Fuse failure supervision based on voltage difference 1MRK004001-HC G03
Control functionality for up to 30 objects 1MRK004001-GZ H39
Transformer insulation loss of life monitoring 1MRK004001-KM M21
9)
Through fault monitoring 1MRK004001-KR M22
Harmonic monitoring 1MRK004001-KS M23
IEC 62439-3 Parallel redundancy protocol 1MRK004001-PP P23
10)
IEC 62439-3 High-availability seamless redundancy 1MRK004001-PR P24
IEC 61850-9-2 Process Bus communication, 8 merging units 1MRK004001-PT P30
Synchrophasor report, 16 phasors 1MRK004001-PX P34
11)
Selection for
position #3
1) All fields in the ordering form do not need to be filled in.
2) A01 only for B30
3) A02 only for A20
4) A31 only for A20
5) A33 only for B30
6) C41 only for A20
7) C42 only for B30/C30
8) D21 only for A20
9) M21 only for B30/C30
10) Options P23 and P24 require two SFPs placed in pairs.
11) This functionality requires accurate time synchronization, therefore eitherPrecision Time Protocol (PTP) Time synch or GTM or IRIG-B will be required.
Language Ordering no #4 Notes and rules
First local HMI user dialogue language
HMI language, English IEC 1MRK002930-AA B1
Additional local HMI user dialogue language
No additional HMI language X0
HMI language, English US 1MRK002920-UB A12
1)
Selection for
position #4
B1
1) Additional 2nd languages are continuously being added. Please get in touch with local ABB sales contact.
Casing Ordering no #5 Notes and rules
1/2 x 19" rack casing, 1 TRM 1MRK000151-VA A
1)
3/4 x 19" rack casing, 2 TRM 1MRK000151-VE C
2)
1/1 x 19" rack casing, 2 TRM 1MRK000151-VD E
Selection for
position #5
1) Only for A20
2) Only for B30/C30
Generator protection REG670
1MRK 502 074-BEN M
Version 2.2
Hitachi Power Grids 151