28. Ordering for Accessories
Accessories
IP15151-1 v1
GPS antenna and mounting details
M12374-3 v5
GPS antenna, including mounting kits Quantity: 1MRK 001 640-AA
Cable for antenna, 20 m (Appx. 65 ft) Quantity: 1MRK 001 665-AA
Cable for antenna, 40 m (Appx. 131 ft) Quantity: 1MRK 001 665-BA
Interface converter (for remote end data communication)
M16668-3 v10
External interface converter from C37.94 (64kbps) to G703 Quantity
:
1 2
1MRK 002 245-AA
External interface converter from C37.94 (64kbps/2Mbps) to G703.E1 Quantity
:
1 2
1MRK 002 245-BA
Test switch
SEMOD111888-5 v13
T
he test system COMBITEST intended for use with the
IEDs is described in 1MRK 512 001-BEN and 1MRK
001024-CA. Please refer to the website:
www.abb.com/protection-control
for detailed
information.
Due to the high flexibility of our product and the wide
variety of applications possible the test switches needs
to be selected for each specific application.
Select your suitable test switch based on the available
contacts arrangements shown in the reference
documentation.
However our proposals for suitable variants are:
Two winding transformer with internal neutral on
current circuits. Two pcs can be used in applications for
three winding transformers in single or multi-breaker
arrangement (ordering number RK926 315-BD)
Two winding transformer with external neutral on
c
urrent circuits. Two pcs can be used in applications for
three winding transformers in single or multi-breaker
arrangement (ordering number RK926 315-BH).
Three winding transformer with internal neutral on
current circuits (ordering number RK926 315-BX).
The normally open "In test mode" contact 29-30 on the
RTXP test switches should be connected to the input of
the test function block to allow activation of functions
individually during testing.
Test switches type RTXP 24 is ordered separately. Please
refer to Section
Related documents
for references to
corresponding documents.
RHGS 6 Case or RHGS 12 Case with mounted RTXP 24
and the on/off switch for DC-supply are ordered
separately. Please refer to Section
Related documents
f
or references to corresponding documents.
Protection cover
M15040-3 v8
Protective cover for rear side of RHGS6, 6U, 1/4 x 19” Quantity:
1MRK 002 420-AE
Protective cover for rear side of terminal, 6U, 1/2 x 19” Quantity: 1MRK 002 420-AC
Protective cover for rear side of terminal, 6U, 3/4 x 19” Quantity: 1MRK 002 420-AB
Protective cover for rear side of terminal, 6U, 1/1 x 19” Quantity:
1MRK 002 420-AA
Generator protection REG670
1MRK 502 074-BEN M
Version 2.2
156 Hitachi Power Grids
© Copyright 2017 Hitachi Power Grids. All rights reserved