1.3 Specifications
Power Requirements Refer to Section 1.2 Model Number Breakdown.
Power Consumption Refer to the signal converter instruction bulletin.
Meter Characteristics
Meter Size/Flow Ca-
pacity
Refer to Table 1-4.
Span Factory set at specified range between extremes listed in
Table 1-4; can be field adjusted.
Rangeability 20:1
Minimum Liquid
Conductivity
20 µS/cm
System Accuracy Refer to the signal converter instruction bulletin.
Meter Capacity Specified on meter data tag (equal to maximum flow capacity in
engineering units). Refer to Table 1-4.
Environmental Limits
Ambient Temperature –13
o
to 140
o
F (–25
o
to 60
o
C)
Relative Humidity 10 to 90% Non-condensing
Process Limits
TABLE 1-1. LIQUID TEMPERATURE
Liner Material
Maximum
Temperature
Minimum
Temperature
TEFLON 356
o
F (180
o
C)
-13
o
F (-25
o
C)
TEFZEL 266
o
F (130
o
C)
Neoprene/Polyurethane 190
o
F (88
o
C)
Hard Rubber, Soft Rubber, LINATEX 175
o
F (80
o
C)
10DS3111E INSTRUCTION MANUAL
1-6