2.2 Meter Handling
When a TEFLON lined meter is specified, two optional liner protector plates (one on each flange
face) are factory installed (when specified at time of order). These plates serve to contain the flared
ends of the liner, and to prevent damage to the liner during installation and handling. These protector
plates are attached to the meter with flat head screws that securely hold the liner in place. If the
pressure on the liner is relieved, the TEFLON will tend to curl away from the flange.
These protector
plates must remain in place when the meter is installed. Refer to Figure 2-1.
During shipment, the liner is protected by wood or composition protectors as shown in Figure 2-2;
these are removed before the meter is installed; leave them in position while moving the meter to the
installation site.
To place the meter in the pipeline a sling and hoist may be necessary. Do not pass a rope or wire
sling through the meter; the liner will be damaged if the meter is supported by the liner. Lift the meter
as shown in Figure 2-2.
Table 2-1 lists the weights of the meters by size and flange classification. Weights shown are
approximate and should be used only as a guide when installing the meter.
TABLE 2-1. METER WEIGHTS
Meter
Size
ANSI Class 150
DIN PN10-16
ANSI Class 300
DIN PN25-40
Inches mm lbs kg lbs kg
125 8 3.5198.4
1
1
⁄
2
40 12 5.3 23 10.1
2 50 16 7.1 27 11.9
3 80 2611.53615.9
4 100 37 16.3 51 22.5
6 150 70 32 140 64
8 200 155 70 210 95
10 250 220 100 295 134
12 300 275 125 365 166
If the continuous submergence option is chosen for Model 10DS3111, the meter weights shown
above must be modified by adding the weights shown in the following table:
TABLE 2-2. CONTINUOUS SUBMERGENCE WEIGHT FACTORS
Meter Size Add to Meter Weight from Table Above
Inches mm lbs kg
125 1.01 .46
1
1
⁄
2
40 0.96 .44
250 1.04 .47
380 1.08 .49
4 100 1.92 .87
6 150 11.23 5.1
8 200 15.57 7.1
10 250 23.27 10.6
12 300 50.47 22.9
10DS3111E INSTRUCTION MANUAL