User’s Manual
ACS 300 Frequency Converters
for Speed Control of
0.55 to 11 kW Squirrel Cage Motors
ACS 300
Question and Answer IconNeed help?

Do you have a question about the ABB ACS 311-1P6-1 and is the answer not in the manual?

ABB ACS 311-1P6-1 Specifications

General IconGeneral
BrandABB
ModelACS 311-1P6-1
CategoryDC Drives
LanguageEnglish

Summary

Safety Instructions

Warnings and Notes

Distinguishes between warnings and notes for safety instructions, detailing conditions that may lead to injury or damage.

General Safety Instructions

States safety instructions intended for all work on the ACS 300, emphasizing qualified electricians and proper earthing.

Emergency Stop Devices

Details requirements for installing emergency stop devices at operator control stations.

Chapter 3 - Power Connections

Insulation Checks

Warns to perform insulation checks before connecting to mains, emphasizing disconnection from power to prevent injury.

Chapter 4 - Control Connections

Chapter 5 - Start-up

Flowchart Commissioning Checklist

Provides a flowchart outlining essential steps for commissioning, including safety, installation, parameters, and test runs.

Chapter 7 - Drive Parameters

Chapter 8 - Fault Tracing

Fault Resetting

Details methods for resetting active faults, including keypad use, Start input deactivation, or power cycling.

Fault Tracing

Provides a comprehensive table listing fault indications, their possible causes, and recommended remedies for troubleshooting.