Chapter 2 – Overview of the ACS 502/504
2-2 ACS 502 Installation & Start-up Manual
Figure 2-1 Explanation of ACS 502/504 Drive Code
ACS 502 - 075 - 4 - 0 0 P 2
AC = AC Drive
Product Type:
S = Standard Product
Family:
50 = ACS 500
Construction
1 = Sizes 002 to 060, Wall Mounted
2 = Sizes 050 to 350, Std Floor Stand Cabinet
4 = Sizes 050 to 350, Module
Output Power (HP, Constant Torque)
Input Voltage
3 = 380-415 VAC
4 = 440-500 VAC
Internal Option 2
0 = No Option
Internal Option 1
2 = I/O Extension Board (SNAT 7520 IOE)
8 = (5) Isolated Digital Inputs (SNAT 763 DII)
9 = 3-15 PSI and (2) Isolated Digital Inputs (SNAT 762 PSI)
0 = No Option
Control Panel
P = Internal Control Panel (Keypad and Display)
0 = No Panel
Protection Class of Enclosure*
0 = Chassis (IP 00)
2 = NEMA 1 (IP 21)
3 = NEMA 1 w/Air Filters
5 = NEMA 12 (IP 54)
*Not all Protection Classes are available for all units.
A = 115 VAC Control Power Board
Dynamic Braking
Blanks = No Brake
1 = Internal Dynamic Brake Chopper Installed
(KVA, Constant Torque for 380 VAC)
6 = 525-600 VAC
3 = Tachometer input option (SNAT 7610 BAC)