Outlines the manual's content and structure.
Specifies the drive types and configurations covered by the manual.
Notes that not all options are available for all drive types.
Emphasizes following safety guidelines from other manuals.
Identifies the intended readers of the manual.
Explains the manual's goal of detailing cabinet options.
Lists other relevant ABB documentation for further information.
Details the default configuration for various drive types and frames.
Describes the standard cabinet's IP21 protection and optional upgrades.
Explains the meaning of IP codes and their numerical designations.
Details the IP22 protection option, including gratings and filter mats.
Describes the IP42 protection option with filter housings and additional fan.
Covers the IP54 protection option with folded board filters and roof fans.
Explains the IP54R option with an air outlet duct collar and filter mats.
Provides formula and example for calculating static pressure for ventilation.
Lists features for marine environments like reinforced mechanics and grab railings.
Details factory inspection features according to UL 508C, including conduit entry.
Outlines features for CSA approval, including cable entry and voltage ratings.
Explains the function of brake choppers for dissipating braking energy.
Describes the option of adding brake resistors to the drive system.
Explains how EMC filters protect against radio-frequency interference.
Defines EMC, drive categories (C2, C3, C4), and TN/IT systems.
Covers EMC filter for category 3 in TN systems, listing availability.
Details EMC filter for category 2 in TN (grounded) systems with frame specifics.
Explains EMC filter for category 3 in TN and IT systems.
Describes the du/dt filter for reducing voltage rise speed and bearing currents.
Explains the sine output filter's function and limitations.
Details the common mode filter for reducing bearing currents.
Summarizes standard line switch and fuse types for various drives.
Describes standard features for ACS800-07 R5-R8, including main switch.
Details standard features for ACS800-U7 R6-R8, including US switch fuse.
Covers standard features for ACS800-07 nxR8i, noting no AC fuses included.
Describes standard features for ACS800-17/37 R6, R7i, R8i with switch fuse.
Details standard features for ACS800-17/37 nxR8i with air circuit breaker.
Explains the line contactor option with manual switch on the door.
Describes replacing aR fuses with gG fuses for specific drive types.
Covers standard and optional use of aR line fuses.
Details the load switch option for specific ACS800-07 nxR8i frames.
Explains load switch options for 12-pulse units.
Describes the air circuit breaker option for isolation and overload protection.
Covers the grounding switch option for temporary grounding.
Details the cabinet heater for preventing condensation.
Lists components included in the cabinet heater option.
Explains the heater's function, power output, and control.
Shows the wiring diagram for the cabinet heater.
Explains the option to use 115 VAC control voltage.
Describes terminals for connecting external control voltage.
Details the option for motor heaters, including control logic.
Covers busbar terminals for connecting busbar trunking systems.
Explains the use of halogen-free components for safety.
Describes options for marking wires and terminals for identification.
Details cable entries at the cabinet roof with grommets.
Explains cable entries at the base of the cabinet with grommets.
Describes US/UK conduit plates for cable entry.
Covers an additional cubicle for motor output terminals.
Describes analog and digital I/O modules for the drive.
Details the standard terminal block for customer control wiring.
Explains thermistor relays for motor overtemperature supervision.
Lists components of the standard thermistor relay option.
Details how thermistor relays detect and indicate motor overtemperature.
Describes Pt100 relays for motor temperature monitoring.
Lists components of the standard Pt100 relay option.
Explains Pt100 relay function for overtemperature supervision.
Guides on setting alarm and trip levels for Pt100 relays.
Explains ATEX certified thermal protection using PTC relays.
Details the ATEX option providing thermal motor protection.
Lists components of the auxiliary motor fan starter option.
Explains how the drive controls the auxiliary motor fan.
Shows the wiring diagram for the auxiliary motor fan starter.
Option to prevent unexpected drive startup.
Implements a Category 0 emergency stop function.
Implements a Category 1 emergency stop function.
Provides earth fault monitoring for ungrounded IT systems.