ABB industrial drives
Description
Cabinet Options for ACS800-07/U7/17/37

Table of Contents

Other manuals for ABB ACS800-07

Question and Answer IconNeed help?

Do you have a question about the ABB ACS800-07 and is the answer not in the manual?

ABB ACS800-07 Specifications

General IconGeneral
BrandABB
ModelACS800-07
CategoryServo Drives
LanguageEnglish

Summary

Introduction to the manual

What this chapter contains

Outlines the manual's content and structure.

Applicability

Specifies the drive types and configurations covered by the manual.

Availability of the options

Notes that not all options are available for all drive types.

Safety instructions

Emphasizes following safety guidelines from other manuals.

Target audience

Identifies the intended readers of the manual.

Purpose of the manual

Explains the manual's goal of detailing cabinet options.

Related documents

Lists other relevant ABB documentation for further information.

Standard features

Standard features of different drive types

Details the default configuration for various drive types and frames.

Degree of protection (B)

General

Describes the standard cabinet's IP21 protection and optional upgrades.

Definitions

Explains the meaning of IP codes and their numerical designations.

IP22 (B053)

Details the IP22 protection option, including gratings and filter mats.

IP42 (B054)

Describes the IP42 protection option with filter housings and additional fan.

IP54 (B055)

Covers the IP54 protection option with folded board filters and roof fans.

IP54R (B059)

Explains the IP54R option with an air outlet duct collar and filter mats.

Calculating the required static pressure difference

Provides formula and example for calculating static pressure for ventilation.

Construction (C)

Marine construction (C121)

Lists features for marine environments like reinforced mechanics and grab railings.

UL listed (C129)

Details factory inspection features according to UL 508C, including conduit entry.

CSA approved (C134)

Outlines features for CSA approval, including cable entry and voltage ratings.

Resistor braking (D)

Brake choppers (D150)

Explains the function of brake choppers for dissipating braking energy.

Brake resistors (D151)

Describes the option of adding brake resistors to the drive system.

Filters (E)

General about EMC filtering

Explains how EMC filters protect against radio-frequency interference.

Definitions

Defines EMC, drive categories (C2, C3, C4), and TN/IT systems.

EMC filter (E200)

Covers EMC filter for category 3 in TN systems, listing availability.

EMC filter (E202)

Details EMC filter for category 2 in TN (grounded) systems with frame specifics.

EMC filter (E210)

Explains EMC filter for category 3 in TN and IT systems.

du/dt filter (E205)

Describes the du/dt filter for reducing voltage rise speed and bearing currents.

Sine output filter (E206)

Explains the sine output filter's function and limitations.

Common mode filter (E208)

Details the common mode filter for reducing bearing currents.

Line options (F)

Standard features of different drive types

Summarizes standard line switch and fuse types for various drives.

ACS800-07 frames R5 to R8

Describes standard features for ACS800-07 R5-R8, including main switch.

ACS800-U7 frames R6 to R8

Details standard features for ACS800-U7 R6-R8, including US switch fuse.

ACS800-07 frames nxR8i

Covers standard features for ACS800-07 nxR8i, noting no AC fuses included.

ACS800-17 and ACS800-37 frames R6, R7i and R8i

Describes standard features for ACS800-17/37 R6, R7i, R8i with switch fuse.

ACS800-17 and ACS800-37 frames nxR8i

Details standard features for ACS800-17/37 nxR8i with air circuit breaker.

Line contactor (F250)

Explains the line contactor option with manual switch on the door.

gG line fuses (F251)

Describes replacing aR fuses with gG fuses for specific drive types.

aR line fuses (F260)

Covers standard and optional use of aR line fuses.

Load-switch (F253)

Details the load switch option for specific ACS800-07 nxR8i frames.

Load-switch for 12-pulse units (+A004+F253)

Explains load switch options for 12-pulse units.

Air circuit breaker (F255)

Describes the air circuit breaker option for isolation and overload protection.

Grounding switch (F259)

Covers the grounding switch option for temporary grounding.

Heaters, external control voltage (G)

Cabinet heater with external supply (G300)

Details the cabinet heater for preventing condensation.

What the option contains

Lists components included in the cabinet heater option.

Description

Explains the heater's function, power output, and control.

Example connection diagram

Shows the wiring diagram for the cabinet heater.

115 V AC control voltage (G304)

Explains the option to use 115 VAC control voltage.

Terminals for external control voltage (G307)

Describes terminals for connecting external control voltage.

Output for motor heater (G313)

Details the option for motor heaters, including control logic.

Busbar supply terminals (G317)

Covers busbar terminals for connecting busbar trunking systems.

Halogen-free materials and wiring (G330)

Explains the use of halogen-free components for safety.

Additional wire markings (G338...G342)

Describes options for marking wires and terminals for identification.

Cabling (H)

Top entry (H351)

Details cable entries at the cabinet roof with grommets.

Top exit (H353)

Explains cable entries at the base of the cabinet with grommets.

US/UK gland/conduit plate (H358)

Describes US/UK conduit plates for cable entry.

Common motor terminal cubicle (H359)

Covers an additional cubicle for motor output terminals.

I/O options (L)

I/O extension and interface modules (+L500, +L501, ...)

Describes analog and digital I/O modules for the drive.

Additional terminal block X2 (+L504)

Details the standard terminal block for customer control wiring.

Thermistor relays (+L505, +2L505)

Explains thermistor relays for motor overtemperature supervision.

What the option contains

Lists components of the standard thermistor relay option.

Description

Details how thermistor relays detect and indicate motor overtemperature.

Pt100 relays (+3L506, +5L506, +8L506)

Describes Pt100 relays for motor temperature monitoring.

What the option contains

Lists components of the standard Pt100 relay option.

Description

Explains Pt100 relay function for overtemperature supervision.

Setting the alarm and trip levels of the Pt100 relay

Guides on setting alarm and trip levels for Pt100 relays.

ATEX certified thermal protection with PTC (+L513)

Explains ATEX certified thermal protection using PTC relays.

Description

Details the ATEX option providing thermal motor protection.

Starter for auxiliary motor fan (M)

General

Lists components of the auxiliary motor fan starter option.

Description

Explains how the drive controls the auxiliary motor fan.

Example connection diagram

Shows the wiring diagram for the auxiliary motor fan starter.

Safety features (Q)

Prevention of Unexpected Start (Q950)

Option to prevent unexpected drive startup.

Category 0 emergency stop (Q951)

Implements a Category 0 emergency stop function.

Category 1 emergency stop (Q952)

Implements a Category 1 emergency stop function.

Earth fault monitoring for IT (ungrounded) systems (Q954)

Provides earth fault monitoring for ungrounded IT systems.