Parameter settings 45
31.11 Fault reset selection
Select the correct source of an external fault reset signal with parameter 31.11 Fault reset
selection.
Other recommended settings
We recommend that you also set these parameters to improve the safety of the
application:
minimum and maximum speeds (parameter group 30)
maximum current, power and torque (group 30)
acceleration and deceleration times
stall protection (parameters 31.24 31.28)
motor load curve (parameters 35.50 35.55)
motor cable protection (parameters 35.60 …. 35.62)
For more information, see the drive firmware manual.