EasyManua.ls Logo

ABB CoriolisMaster FCB430 - Page 51

ABB CoriolisMaster FCB430
148 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CoriolisMaster FCB400, FCH400 CORIOLIS MASS FLOWMETER | OI/FCB400/FCH400-EN REV. E 51
Digital output 41 / 42, 51 / 52 (basic device)
Can be configured as pulse, frequency or binary output via on-
site software.
G11597-02
A
16...30 V DC
B
R
B
U
CE
I
CE
R
B
U
CE
I
CE
41+
51+
IE
42-/
52-
41+
51+
IE
42-/
52-
R
B
R
B
012345
16...30 V DC
012345
R
B
A Digital output 41 / 42, 51 / 52 passive as a pulse of frequency output
B Passive digital output 51 / 52 as binary output
Figure 35: (I = internal, E = external, R
B
= load)
Pulse / frequency output (passive)
Terminals 41 / 42, 51 / 52
Output ‘closed’ 0 V U
CEL
3 V
For f < 2.5 kHz: 2 mA < I
CEL
< 30 mA
For f > 2.5 kHz: 10 mA < I
CEL
< 30 mA
Output ‘open’ 16 V U
CEH
30 V DC
0 mA I
CEH
0.2 mA
f
max
10.5 kHz
Pulse width 0.1 to 2000 ms
Binary output (passive)
Terminals 41 / 42, 51 / 52
Output ‘closed’ 0 V U
CEL
3 V
2 mA I
CEL
30 mA
Output ‘open’ 16 V U
CEH
3 V DC
0 mA I
CEH
0.2 mA
Switching function Can be configured using software.
See Menu: Input / Output on page 107.
Note
Terminals 42 / 52 have common grounding. Digital outputs
41 / 42 and 51 / 52 are not electrically isolated from each
other. An electrically isolated digital output can be made
using a plug-in module.
If using a mechanical counter, it is advisable to set a pulse
width of 30 ms and a maximum frequency of fmax 3 kHz.
Current output V1 / V2, V3 / V4 (plug-in module)
Up to two additional plug-in modules can be implemented via
the ‘Passive current output (red)’ option module.
Can be configured for outputting mass flow, volume flow,
density and temperature via on-site software.
G11897-02
A
B
V1+
IE
V2-
R
B
OC1
V3+
IE
V4-
R
B
OC2
A Current output V1 / V2, passive B Current output V3 / V4, passive
Figure 36: (I = internal, E = external, R
B
= load)
The plug-in module can be used in slot OC1 and OC2.
G10323-02
0
0
100
200
300
400
500
600
5101520253035
RB [Ω]
Uq [V]
Permissible source voltage U
q
for passive outputs in relation to load
resistance R
B
where Imax = 22 mA.  = Permissible range
Figure 37: Source voltage for passive outputs
Passive current output
Terminals V1 / V2, V3 / V4
Output signal 4 to 20 mA
Load R
B
250 Ω R
B
600 Ω
Source voltage U
q
* 13 V U
q
30 V
Measuring error < 0.1 % of measured value
Resolution 0.4 µA per digit
* The source voltage U
q
is dependent of the load R
B
and must be placed in
an additional area.