5.3.2 Output Size
Parent
Output Size belongs to the type Internal Anybus Device, in the topic I/O System.
Cfg name
OutputSize
Description
The parameter Output Size defines the data size in bytes for the input area sent
to the PROFINET Master.
Usage
Output Size is a PROFINET specific parameter.
Prerequisites
The option PROFINET Anybus Device must be installed.
Limitations
A limitation is the maximum device size for the Internal Anybus Device
Allowed values
Allowed values are the integers 1-128 (8-1024 signal bits).
The default value is 64 (512 signal bits).
Additional information
Any other values than 1, 2, 4, 8, 16, 32, 64, or 128 will result in digital output size
rounded up to the closest of these values.
Application manual - PROFINET Anybus Device 41
3HAC050968-001 Revision: C