      Summary

      EN - R0…R4 Quick installation guide

      Obey the safety instructions

      Crucial safety warnings to prevent injury, death, or equipment damage during installation.

      Check capacitor reforming needs

      Determine if capacitors require reforming if the drive has been unpowered for over one year.

      Power cable selection and protection

      Guidelines for selecting, sizing, and protecting power cables and motor connections, including insulation checks.

      Drive installation and cooling

      Instructions for wall mounting the drive and ensuring adequate cooling for optimal operation.

      System compatibility and component disconnection

      Verifying compatibility with IT/TN systems and instructions for disconnecting EMC filters or varistors.

      Connect power cables

      Detailed steps for connecting motor power, input power cables, and brake resistor cables.

      Connect control cables

      Steps for routing and connecting analog/digital signal cables to the control board.

      Default I;O connections

      Diagram illustrating the default Input/Output connections for the ABB standard macro.

      Optional modules and cover reinstallation

      Guidance on installing optional modules and reinstalling the drive covers after completing the setup.

      ABB ACS580-01 drives Specifications

      General IconGeneral
      Control methodScalar control, Vector control
      Frequency0 to 500 Hz
      Communication protocolsModbus RTU, Ethernet/IP, Profibus DP, CANopen
      Protection featuresOvercurrent, overvoltage, undervoltage
      Enclosure ratingIP21, IP55
      Ambient temperature-15 to +50 °C
      Storage temperature-40 to +70 °C
      Relative humidity5 to 95% (non-condensing)
      AltitudeUp to 1000 m (without derating), up to 4000 m (with derating)
      EMC FilterBuilt-in
      Voltage range208 to 480 V
      Braking ChopperBuilt-in up to 22 kW