Do you have a question about the ABB HygienicMaster FEH631 and is the answer not in the manual?
Type | Electromagnetic flowmeter |
---|---|
Lining material | PFA |
Pressure rating | Max. 40 bar (580 psi) |
Material | Stainless Steel |
Application | Hygienic applications |
Process connection | Tri-Clamp |
Electrode material | Stainless steel, Tantalum |
Accuracy | ±0.2% of rate |
Fluid temperature | Up to 150°C (302°F) |
Process Temperature Range | Up to 150°C (302°F) |
Ambient temperature | -20 to 60 °C (-4 to 140 °F) |
Protection class | IP66/67 |
Output signal | 4-20 mA, pulse, frequency |
Communication | HART, Modbus |
Power supply | 24 V DC |
Certifications | EHEDG, 3-A, FDA |
Explanation of warning signal words (DANGER, WARNING, CAUTION, NOTICE) and their meanings.
Specific safety requirements for installation in explosive atmospheres.
Requirements for connecting the flowmeter sensor to ground potential.
General information and specific methods for grounding the sensor.
Requirements and connection details for the device's power supply.
Diagrams and tables showing terminal connections for power and I/O.
Essential checks to perform before commissioning the device.
Fastest method for configuring common parameters via the 'Easy Setup' menu.
Accessing parameters for device configuration and changing settings.
Table of error codes, LCD text, cause, and remedy.
Safety warnings for repair activities, including explosion, live parts, and hot media.