2 FEP630, FEH630 ELECTROMAGNETIC FLOWMETER | OI/FEP630/FEH630-EN REV. D
Table of contents
Change from one to tw o columns
1 Safety .......................................................................... 4
General information and instructions .................................. 4
Warnings .................................................................................... 4
Intended use ............................................................................. 5
Improper use ............................................................................. 5
Use in Potentially Explosive Atmospheres .......................... 5
Notes on data safety ............................................................... 5
Warranty provisions ................................................................. 6
Manufacturer’s address .......................................................... 6
2 Design and function .................................................. 7
Overview .................................................................................... 7
ProcessMaster ..................................................................... 7
HygienicMaster .................................................................... 8
Transmitter .......................................................................... 9
Model variants ........................................................................ 10
Measuring principle ............................................................... 11
3 Product identification ............................................ 12
Name plate .............................................................................. 12
Additional warning plate ...................................................... 12
4 Transport and storage ............................................ 13
Inspection ................................................................................ 13
Transport ................................................................................. 13
Storing the device .................................................................. 14
Temperature data .................................................................. 14
Returning devices ................................................................... 14
5 Installation ............................................................... 15
Safety instructions ................................................................. 15
Use in Potentially Explosive Atmospheres ................... 15
Installation conditions .......................................................... 15
General ................................................................................ 15
Devices with extended diagnostic functions ............... 15
Brackets .............................................................................. 16
Gaskets................................................................................ 16
Devices with a wafer-type design .................................. 16
Flow direction .................................................................... 16
Electrode axis ..................................................................... 17
Mounting position............................................................. 17
Minimum spacing of the devices .................................... 17
Grounding ........................................................................... 18
Sensor insulation ............................................................... 18
Inlet and outlet sections .................................................. 18
Free inlet or outlet ............................................................. 19
Mounting with heavily contaminated measuring media
.............................................................................................. 19
Mounting with pipe vibration ......................................... 19
Installation in piping with larger nominal diameter ... 20
Installation in 3A compliant installations ..................... 20
Installing the sensor .............................................................. 21
Installing the transmitter in the remote mount design .. 22
Opening and closing the housing ....................................... 23
Adjusting the transmitter position ..................................... 24
Installing the plug-in cards ................................................... 26
6 Electrical connections .............................................29
Safety instructions ................................................................ 29
Use in Potentially Explosive Atmospheres ................... 29
Sensor grounding .................................................................. 29
General information on grounding ................................ 29
Metal pipe with fixed flanges ......................................... 30
Metal pipe with loose flanges ......................................... 30
Plastic pipes, non-metallic pipes or pipes with
insulating liner ................................................................... 30
Sensor type HygienicMaster ............................................ 31
Grounding with conductive PTFE grounding plate ..... 31
Devices with extended diagnostic functions ............... 31
Installation and grounding in piping with cathodic
corrosion protection ......................................................... 31
Power supply .......................................................................... 33
Cable entries ........................................................................... 34
Connection via cable conduit ......................................... 34
Installing the connection cables ......................................... 34
Connection with IP rating IP 68 ........................................... 35
Pin assignment ....................................................................... 37
Electrical data for inputs and outputs .......................... 38
Connection examples ....................................................... 42
Connection to integral mount design ........................... 44
Connection to remote mount design ........................... 46
Digital communication ......................................................... 49
HART® communication .................................................... 49
Modbus® communication ............................................... 49
Cable specification ........................................................... 50
PROFIBUS DP® communication ...................................... 50
7 Commissioning ........................................................ 52
Safety instructions ................................................................ 52
Use in Potentially Explosive Atmospheres ................... 52
Hardware settings ................................................................. 52
Dual- compartment housing ........................................... 52
Single-compartment housing ......................................... 53
Configuration of digital outputs V1 / V2 or V3 / V4 ... 53
Checks prior to commissioning .......................................... 54
Parameterization of the device ........................................... 54
Parameterization via the local operating interface .... 54
Parameterization via the infrared service port adapter
.............................................................................................. 55
Parameterization via HART® ........................................... 55
Factory settings ..................................................................... 56
Switching on the power supply ........................................... 56
Parameterization via the menu function Easy Setup ...... 56
Measuring range table .......................................................... 60

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB HygienicMaster FEH631 and is the answer not in the manual?

ABB HygienicMaster FEH631 Specifications

General IconGeneral
TypeElectromagnetic flowmeter
Lining materialPFA
Pressure ratingMax. 40 bar (580 psi)
MaterialStainless Steel
ApplicationHygienic applications
Process connectionTri-Clamp
Electrode materialStainless steel, Tantalum
Accuracy±0.2% of rate
Fluid temperatureUp to 150°C (302°F)
Process Temperature RangeUp to 150°C (302°F)
Ambient temperature-20 to 60 °C (-4 to 140 °F)
Protection classIP66/67
Output signal4-20 mA, pulse, frequency
CommunicationHART, Modbus
Power supply24 V DC
CertificationsEHEDG, 3-A, FDA