FEP630, FEH630 ELECTROMAGNETIC FLOWMETER  |  OI/FEP630/FEH630-EN REV. D  9 
 
 
 
Transmitter 
 
 
1  Dual-compartment transmitter housing   
 
2  Single-compartment transmitter housing 
Figure 3:  Designs 
 
Transmitter 
Model  FET632 
Housing  Integral mount design, remote mount design 
IP rating  IP 65 / IP 67 / NEMA 4X 
Cable length  Maximum 200 m (656 ft), remote mount design only 
Power supply  100 to 240 V AC (−15 / +10 %) 50 / 60 Hz, 16.8 to 30 V DC 
Outputs  Current output: 4 to 20 mA active or passive (can be configured on-site) 
Digital output 1: passive, configurable as pulse, frequency or switch output 
Digital output 2: passive, configurable as pulse or switch output 
Additional outputs  The transmitter has two slots which can be used to insert plug-in cards to extend the outputs. 
The following plug-in cards are available: 
•  Current output (passive) 
•  Digital output (passive) 
•  Digital input (passive): 
•  24 V DC power supply for active outputs 
Communication  Standard: HART® 7.1 
Option: PROFIBUS DP® / Modbus® 
 
Approvals 
 
Explosion protection (in preparation)  ATEX / IECEx Zone 1, 2, 21, 22 
FM / cFM Cl 1 Div 1, Cl 1 Div 2 
Additional approvals  At www.abb.com/flow or on request. 
 
 