Quick installation guide - MotiFlex e180
5
Cabling examples
Wire sizes accepted by power terminals
Tightening torques
MFE180-04xx-02A5…016A-4
1
2
3
MFE180-04xx-024A…090A-4
2
4
1
3
Drive type MFE180-04xx… Wire size
-02A5…07A0-4 0.25 … 4 mm
2
-09A5…016A-4 0.5 … 6 mm
2
-024A…090A-4 6 … 70 mm
2
Drive type
MFE180-04xx…
Power terminals (supply,
motor, and braking resistor
cables)
Screw lug
(Allen screw)
N·m (lbf·in) N·m (lbf·ft)
-02A5…07A0-4 0.5 … 0.6 (4.4 … 5.3) N/A
-09A5…016A-4 1.2 … 1.5 (10.6 … 13.3) N/A
-024A…090A-4 3 (25) 15 (11)
Drive type
MFE180-04xx…
PE/Ground
terminals
Power cable
clamps
Power
connector
covers
N·m (lbf·in) N·m (lbf·in) N·m (lbf·in)
-02A5…07A0-4 1.5 (13) 1.5 (13) N/A
-09A5…016A-4 1.5 (13) 1.5 (13) N/A
-024A…090A-4 3 (25) 1.5 (13) 3 (25)
Cable clamp on bare shield.
PE/Ground connection.
Between cable clamp and terminals, cover bare
shield with insulating tape.
Screw lug detail: