EasyManua.ls Logo

ABB MT series - User Manual

ABB MT series
160 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Installation, operation, maintenance and safety manual .......................................................................................... EN 3
Montage-, Betriebs-, Wartungs- und Sicherheitsanleitung .................................................................................... DE 21
Manuel d’installation, d’exploitation, de maintenance et de sécurité ..................................................................... FR 39
Manual de instalación, funcionamiento, mantenimiento y seguridad ..................................................................... ES 59
Manuale d’installazione, funzionamento e manutenzione ........................................................................................ IT 79
Manual de instalação, operação, manutenção e segurança ...................................................................................PT 99
Installations-, driffts-, underhålls- och säkerhetsmanual ..................................................................................... SV 119
Asennus-, käyttö-, kunnossapito- ja turvallisuusohje ............................................................................................ FI 137
More languages – see web site www.abb.com/motors&generators > Motors > Document library
Low voltage motors
Manual

Table of Contents

Other manuals for ABB MT series

Questions and Answers

  • P
    porterrichardAug 19, 2025
    Why does my ABB MT Engine overheat while running?
    • J
      Jennifer GrayAug 19, 2025
      If your ABB Engine overheats while running, it could be due to several reasons. First, try reducing the load on the motor. Check the frame and ventilation openings for dirt that may be preventing proper ventilation, and ensure a continuous stream of air is flowing from the motor. Make sure all leads are well connected, as one phase might be open. If there is a grounded coil, the motor will need to be rewound. Finally, check for faulty leads, connections, and transformers if the terminal voltage is unbalanced.
  • A
    Ashley KentAug 22, 2025
    What to do if ABB MT stalls?
    • A
      Anthony PittmanAug 23, 2025
      If your ABB Engine stalls, it could be due to several reasons. Check the lines for an open phase. If the application is wrong, change the type or size and consult the equipment supplier. Reduce the load if there is an overload. Ensure the rating plate voltage is maintained and check the connection if the voltage is low. Check the overload relay, stator, and push buttons; blown fuses could indicate an open circuit.
  • D
    Dustin VillanuevaAug 26, 2025
    Why ABB MT takes too long to accelerate and/or draws high current?
    • A
      Alison SimsAug 26, 2025
      If your ABB Engine takes too long to accelerate or draws high current, there are several potential causes. Try reducing the load. Check for high resistance and ensure adequate cable size if the voltage is low during start. If the squirrel cage rotor is defective, replace it. Finally, correct the power supply if the applied voltage is too low.
  • M
    mariathomasAug 28, 2025
    What causes ABB MT to vibrate?
    • J
      Jason AndrewsAug 28, 2025
      If your ABB Engine vibrates, several factors could be the cause. Realign the motor if it is misaligned. Strengthen the base if the support is weak. Balance the coupling if it is out of balance. Rebalance the driven equipment if it is unbalanced. Replace defective bearings. Repair the motor if the bearings are not in line. Rebalance the motor if the balancing weights have shifted. Rebalance the coupling or motor if there is a contradiction between the balancing of the rotor and coupling. Check for an open circuit if the polyphase motor is running single phase. Adjust the bearing or add a shim if there is excessive end play.
  • M
    Maria OlsenAug 30, 2025
    Why ABB MT does not come up to nominal speed?
    • E
      Emily BoyleAug 30, 2025
      If the ABB Engine does not reach its nominal speed, it might not be applied properly, so consult the equipment supplier for the correct type. Low voltage at the motor terminals due to line drop can also be a factor; use a higher voltage or transformer terminals, or reduce the load, and check the connections and conductors for proper size. Check the start load of the motor if the starting load is too high. Look for cracks near the rings if there are broken or loose rotor bars, and consider replacing the rotor, as repairs are usually temporary. Locate and repair any faults with a testing device if there's an open primary circuit.
  • P
    Paul JosephSep 2, 2025
    What to do if ABB MT runs and then dies down?
    • J
      justin47Sep 2, 2025
      If your ABB Engine runs and then dies down, check for loose connections to the line, fuses, and control, as the issue may be a power failure.
  • L
    lauren12Sep 7, 2025
    Why is my ABB Engine making a scraping noise?
    • W
      Whitney LucasSep 7, 2025
      If your ABB Engine is making a scraping noise, correct the fan mounting if the fan is rubbing against the end shield or fan cover. Tighten the holding bolts if it is loose on the bedplate.
  • E
    Edward MillerSep 12, 2025
    How to fix wrong rotation direction of ABB MT Engine?
    • B
      Bryan RiveraSep 12, 2025
      To correct the rotation direction of your ABB Engine, reverse the connections at the motor or at the switchboard, as the wrong sequence of phases is the cause of this problem.
  • H
    Howard FieldsSep 13, 2025
    Why is my ABB MT making noisy operation?
    • T
      tgonzalezSep 13, 2025
      If your ABB Engine is operating noisily, check and correct the end shield fits or bearing fits, as a non-uniform air gap could be the cause. If there is rotor unbalance, rebalance the rotor.
  • W
    William RamosNov 16, 2025
    How to troubleshoot ABB MT Engine that fails to start?
    • S
      Samuel AndersonNov 16, 2025
      If your ABB Engine fails to start, several issues could be the cause. First, check for blown fuses and replace them with the correct type and rating. Next, verify if the overload has tripped and reset it in the starter. Ensure the power supply matches the motor's rating plate and load factor. Also, check the wiring connections against the diagram provided with the motor. Listen for a humming sound, which indicates an open circuit; inspect for loose wiring and ensure all control contacts are closing. Finally, check for mechanical failures by ensuring the motor and drive turn freely and inspect the bearings and lubrication. If fuses are blown, and there is a short-circuited stator, the motor must be rewound. Look for broken bars or end rings if the rotor is defective. Reduce the load if the ...

Summary

Handling

Installation and commissioning

Insulation resistance check

Measure insulation resistance before commissioning and if dampness is suspected.

Mounting and alignment of the motor

Ensure adequate airflow. Correct alignment prevents bearing, vibration, and shaft failures.

Operation

Safety considerations

Intended for qualified personnel. Use necessary safety equipment according to local regulations.

Low voltage motors in variable speed operation

Winding insulation

Higher voltage stresses occur with VSDs. Dimension winding insulation and filters accordingly.

Selection of winding insulation for ACS800 and ACS550 converters

Guide to selecting winding insulation and filters for ACS800/ACS550 converters based on voltage and cable length.

Bearing currents

Use insulated bearings, filters, and grounding methods to prevent harmful bearing currents.

Elimination of bearing currents with ABB ACS800 and ACS550 converters

Methods to avoid bearing currents in motors with ABB ACS800/ACS550 converters with diode supply.

Cabling, grounding and EMC

Use shielded cables and EMC glands for 360° bonding. Ensure proper grounding for EMC compliance.

Dimensioning the motor for variable speed application

Dimension motors using ABB's DriveSize program or manually for other converters.

Dimensioning with ABB ACS800 converters with DTC control

Loadability curves for ACS800 converters with DTC show output torque versus frequency.

Dimensioning with ABB ACS550 converters

Loadability curves for ACS550 converters show output torque as a function of supply frequency.

Maintenance

Lubrication

Lubrication intervals are based on the L₁-principle for reliability. Consult ABB for specific needs.

Lubricants

Recommended greases: Esso Unirex N2/N3, Mobilith SHC 100. Do not mix different grease types.

Troubleshooting

Motor fails to start

Troubleshoot motor start failure: check fuses, overload trips, power supply, and connections.

Motor stalls

Troubleshoot motor stalling: check overload, phase loss, mechanical issues, or incorrect application.

Motor runs and then dies down

Troubleshoot motor shutdown: check power failure, low voltage, or open circuit issues.

Motor does not come up to nominal speed

Troubleshoot speed issues: check voltage, line drop, starting load, or connections.

Motor overheats while running

Troubleshoot overheating: check ventilation, dirt, open phase, coil faults, or alignment.