Loop 1
33
Loop 1
Decimal Read Write Variable Data type Comment
hexadecimal hexadecimal name
227 0x00E3 0xFF1D .INDS_LOOP1 INT Display loop position
1822 0x071E 0xF8E2 .L1_A_VORB BOOL AUTOMATIC mode ready
245 0x00F5 0xFF0B .L1_ANA_LO REAL Lower bargraph scaling
247 0x00F7 0xFF09 .L1_ANA_HI REAL Upper bargraph scaling
1821 0x071D 0xF8E3 .L1_B1 BOOL Change-over ES1/ES2
225 0x00E1 0xFF1F .L1_BA_YOUT REAL Output variable feedback signal
1825 0x0721 0xF8DF .L1_BETART_UM BOOL Request mode change-over
1824 0x0720 0xF8E0 .L1_C_VORB BOOL CASCADE mode ready
827 0x033B 0xFCC5 .L1_D REAL Signal for D of PID
291 0x0123 0xFEDD .L1_D1 DINT Free DINT variable
293 0x0125 0xFEDB .L1_D2 DINT Free DINT variable
295 0x0127 0xFED9 .L1_D3 DINT Free DINT variable
297 0x0129 0xFED7 .L1_D4 DINT Free DINT variable
151 0x0097 0xFF69 .L1_ES1 REAL 1st. input of input circuit
153 0x0099 0xFF67 .L1_ES2 REAL 2nd. input of input circuit
155 0x009B 0xFF65 .L1_ES3 REAL 3rd. input of input circuit
157 0x009D 0xFF63 .L1_ES4 REAL 4th. input of input circuit
159 0x009F 0xFF61 .L1_ES5 REAL 5th. input of input circuit
1834 0x072A 0xF8D6 .L1_GW1_OUT BOOL Violation of limit value L1-LV1
1835 0x072B 0xF8D5 .L1_GW2_OUT BOOL Violation of limit value L1-LV2
1836 0x072C 0xF8D4 .L1_GW3_OUT BOOL Violation of limit value L1-LV3
1837 0x072D 0xF8D3 .L1_GW4_OUT BOOL Violation of limit value L1-LV4
1829 0x0725 0xF8DB .L1_HAND_M BOOL Step output MORE
1830 0x0726 0xF8DA .L1_HAND_W BOOL Step output LESS
177 0x00B1 0xFF4F .L1_K1 REAL Evaluation factor K1
179 0x00B3 0xFF4D .L1_K2 REAL Evaluation factor K2
181 0x00B5 0xFF4B .L1_K3 REAL Evaluation factor K3
183 0x00B7 0xFF49 .L1_K4 REAL Evaluation factor K4
943 0x03AF 0xFC51 .L1_K5 REAL Evaluation factor K5
945 0x03B1 0xFC4F .L1_K6 REAL Evaluation factor K6
947 0x03B3 0xFC4D .L1_K7 REAL Evaluation factor K7
949 0x03B5 0xFC4B .L1_K8 REAL Evaluation factor K8
951 0x03B7 0xFC49 .L1_K9 REAL Evaluation factor K9
953 0x03B9 0xFC47 .L1_K10 REAL Evaluation factor K10
955 0x03BB 0xFC45 .L1_K11 REAL Evaluation factor K11
957 0x03BD 0xFC43 .L1_K12 REAL Evaluation factor K12
959 0x03BF 0xFC41 .L1_K13 REAL Evaluation factor K13
961 0x03C1 0xFC3F .L1_K14 REAL Evaluation factor K14
963 0x03C3 0xFC3D .L1_K15 REAL Evaluation factor K15
965 0x03C5 0xFC3B .L1_K16 REAL Evaluation factor K16
199 0x00C7 0xFF39 .L1_KP_STEUER REAL Effective P-gain
201 0x00C9 0xFF37 .L1_KS_STEUER REAL Effective amplification constant Ks
249 0x00F9 0xFF07 .L1_LAMBDA REAL
1823 0x071F 0xF8E1 .L1_M_VORB BOOL MAN mode ready
1840 0x0730 0xF8D0 .L1_MAN_AUTO BOOL Controller in AUTO or MAN mode
1841 0x0731 0xF8CF .L1_MAN_CAS BOOL Controller in CASCADE or MAN mode
215 0x00D7 0xFF29 .L1_PID_D_OUT REAL D-Portion of output signal
213 0x00D5 0xFF2B .L1_PID_I_OUT REAL I-Portion of output signal
1838 0x072E 0xF8D2 .L1_PID_PS BOOL Change-over parameter set 1<->2
831 0x033F 0xFCC1 .L1_PID_Y_OUT REAL Cont. output signal
271 0x010F 0xFEF1 .L1_R1 REAL Free REAL variable
273 0x0111 0xFEEF .L1_R2 REAL Free REAL variable
275 0x0113 0xFEED .L1_R3 REAL Free REAL variable
277 0x0115 0xFEEB .L1_R4 REAL Free REAL variable
279 0x0117 0xFEE9 .L1_R5 REAL Free REAL variable
281 0x0119 0xFEE7 .L1_R6 REAL Free REAL variable
283 0x011B 0xFEE5 .L1_R7 REAL Free REAL variable
285 0x011D 0xFEE3 .L1_R8 REAL Free REAL variable
1826 0x0722 0xF8DE .L1_REGLER_AUTO BOOL Controller AUTO
1828 0x0724 0xF8DC .L1_REGLER_C BOOL Controller CASCADE
1827 0x0723 0xF8DD .L1_REGLER_MAN BOOL Controller MAN
221 0x00DD 0xFF23 .L1_SCAL_LO REAL Lower control loop scaling
223 0x00DF 0xFF21 .L1_SCAL_HI REAL Upper control loop scaling
1844 0x0734 0xF8CC .L1_SETZ_AUTO BOOL Change-over to automatic mode
1845 0x0735 0xF8CB .L1_SETZ_CASC BOOL Change-over to cascade mode