40
Loop 4
Decimal Read Write Variable Data type Comment
hexadecimal hexadecimal name
1963 0x07AB 0xF855 .L4_SETZ_MAN BOOL Change-over to man. mode
1052 0x041C 0xFBE4 .L4_SETZ_W INT Change-over to setpoint source
719 0x02CF 0xFD31 .L4_SKALV REAL Scaling factor ratio with LOAD AIR
1959 0x07A7 0xF859 .L4_SPAKTIV BOOL Auto-configuration active
737 0x02E1 0xFD1F .L4_T1 DINT Free time variable
661 0x0295 0xFD6B .L4_T1_STEUER REAL Effective delay time T1
739 0x02E3 0xFD1D .L4_T2 DINT Free time variable
645 0x0285 0xFD7B .L4_TIME_DPS_MAN DINT Step output increment [ms]
653 0x028D 0xFD73 .L4_TN_STEUER REAL Effective integral action time [min]
659 0x0293 0xFD6D .L4_TT_STEUER REAL Effective dead time Tt [min]
655 0x028F 0xFD71 .L4_TV_STEUER REAL Effective derivative action time [min]
691 0x02B3 0xFD4D .L4_V REAL Setpoint ratio
1953 0x07A1 0xF85F .L4_V_F BOOL Fixed value/ratio status
693 0x02B5 0xFD4B .L4_VISTDIGI REAL Actual ratio
707 0x02C3 0xFD3D .L4_W_FOLGE REAL Setpoint for slave control in cascade
1952 0x07A0 0xF860 .L4_W_STATUS BOOL
883 0x0373 0xFC8D .L4_WAKT REAL Current setpoint
623 0x026F 0xFD91 .L4_WANA REAL
703 0x02BF 0xFD41 .L4_WANA_SKAL REAL SP bargraph
679 0x02A7 0xFD59 .L4_WCOMPUTER REAL Computer target setpoint
625 0x0271 0xFD8F .L4_WDIGI REAL Current setpoint
717 0x02CD 0xFD33 .L4_WEXT REAL External setpoint
1962 0x07AA 0xF856 .L4_WEXT_AKTIV BOOL External SP active
681 0x02A9 0xFD57 .L4_WSOLL0 REAL Target setpoint 1
683 0x02AB 0xFD55 .L4_WSOLL1 REAL Target setpoint 2
685 0x02AD 0xFD53 .L4_WSOLL2 REAL Target setpoint 3
687 0x02AF 0xFD51 .L4_WSOLL3 REAL Target setpoint 4
881 0x0371 0xFC8F .L4_WW REAL Effective setpoint
617 0x0269 0xFD97 .L4_XANA REAL
701 0x02BD 0xFD43 .L4_XANA_SKAL REAL PV bargraph
885 0x0375 0xFC8B .L4_XDIGI REAL Digital display PV
889 0x0379 0xFC87 .L4_XW REAL Control deviation in engineering units
637 0x027D 0xFD83 .L4_XW_EU REAL Control deviation in engineering units
639 0x027F 0xFD81 .L4_XW_PRZ REAL Control deviation in %
657 0x0291 0xFD6F .L4_Y0_STEUER REAL Effective operating point [%]
705 0x02C1 0xFD3F .L4_YCOMPUTER REAL OUT COMPUTER with DDC
647 0x0287 0xFD79 .L4_YHAND REAL Man. value of output variable
641 0x0281 0xFD7F .L4_YMAX REAL Max. output value
711 0x02C7 0xFD39 .L4_YMAX_BR REAL Override selection for override controller
715 0x02CB 0xFD35 .L4_YMAX_HR REAL Override selection for master controller, MIN. selection
643 0x0283 0xFD7D .L4_YMIN REAL Min. output value
709 0x02C5 0xFD3B .L4_YMIN_BR REAL OUT-Min override selection for override controller
713 0x02C9 0xFD37 .L4_YMIN_HR REAL Override selection for master controller, MAX.
selection
669 0x029D 0xFD63 .L4_YSRUECK REAL Position feedback
613 0x0265 0xFD9B .L4_YTRACK REAL OUT tracking signal in AUTO mode
1798 0x0706 0xF8FA .SLH_LOOP4 BOOL Loop 4 in display
799 0x031F 0xFCE1 .WW_LOOP4 INT Index of selected setpoint loop 4