Loop 4
39
Loop 4
Decimal Read Write Variable Data type Comment
hexadecimal hexadecimal name
677 0x02A5 0xFD5B .INDS_LOOP4 INT Display loop position
1942 0x0796 0xF86A .L4_A_VORB BOOL AUTOMATIC mode ready
695 0x02B7 0xFD49 .L4_ANA_LO REAL Lower bargraph scaling
697 0x02B9 0xFD47 .L4_ANA_HI REAL Upper bargraph scaling
1941 0x0795 0xF86B .L4_B1 BOOL Change-over ES1/ES2
675 0x02A3 0xFD5D .L4_BA_YOUT REAL Output variable feedback signal
1945 0x0799 0xF867 .L4_BETART_UM BOOL Request mode change-over
1944 0x0798 0xF868 .L4_C_VORB BOOL CASCADE mode ready
887 0x0377 0xFC89 .L4_D REAL Signal for D of PID
741 0x02E5 0xFD1B .L4_D1 DINT Free DINT variable
743 0x02E7 0xFD19 .L4_D2 DINT Free DINT variable
745 0x02E9 0xFD17 .L4_D3 DINT Free DINT variable
747 0x02EB 0xFD15 .L4_D4 DINT Free DINT variable
601 0x0259 0xFDA7 .L4_ES1 REAL 1st. input of input circuit
603 0x025B 0xFDA5 .L4_ES2 REAL 2nd. input of input circuit
605 0x025D 0xFDA3 .L4_ES3 REAL 3rd. input of input circuit
607 0x025F 0xFDA1 .L4_ES4 REAL 4th. input of input circuit
609 0x0261 0xFD9F .L4_ES5 REAL 5th. input of input circuit
1954 0x07A2 0xF85E .L4_GW1_OUT BOOL Violation of limit value L4-LV1
1955 0x07A3 0xF85D .L4_GW2_OUT BOOL Violation of limit value L4-LV2
1956 0x07A4 0xF85C .L4_GW3_OUT BOOL Violation of limit value L4-LV3
1957 0x07A5 0xF85B .L4_GW4_OUT BOOL Violation of limit value L4-LV4
1949 0x079D 0xF863 .L4_HAND_M BOOL Step output MORE
1950 0x079E 0xF862 .L4_HAND_W BOOL Step output LESS
627 0x0273 0xFD8D .L4_K1 REAL Evaluation factor K1
629 0x0275 0xFD8B .L4_K2 REAL Evaluation factor K2
631 0x0277 0xFD89 .L4_K3 REAL Evaluation factor K3
633 0x0279 0xFD87 .L4_K4 REAL Evaluation factor K4
1015 0x03F7 0xFC09 .L4_K5 REAL Evaluation factor K5
1017 0x03F9 0xFC07 .L4_K6 REAL Evaluation factor K6
1019 0x03FB 0xFC05 .L4_K7 REAL Evaluation factor K7
1021 0x03FD 0xFC03 .L4_K8 REAL Evaluation factor K8
1023 0x03FF 0xFC01 .L4_K9 REAL Evaluation factor K9
1025 0x0401 0xFBFF .L4_K10 REAL Evaluation factor K10
1027 0x0403 0xFBFD .L4_K11 REAL Evaluation factor K11
1029 0x0405 0xFBFB .L4_K12 REAL Evaluation factor K12
1031 0x0407 0xFBF9 .L4_K13 REAL Evaluation factor K13
1033 0x0409 0xFBF7 .L4_K14 REAL Evaluation factor K14
1035 0x040B 0xFBF5 .L4_K15 REAL Evaluation factor K15
1037 0x040D 0xFBF3 .L4_K16 REAL Evaluation factor K16
649 0x0289 0xFD77 .L4_KP_STEUER REAL Effective P-gain
651 0x028B 0xFD75 .L4_KS_STEUER REAL Effective amplification constant Ks
699 0x02BB 0xFD45 .L4_LAMBDA REAL
1943 0x0797 0xF869 .L4_M_VORB BOOL MAN mode ready
1960 0x07A8 0xF858 .L4_MAN_AUTO BOOL Controller in AUTO or MAN
1961 0x07A9 0xF857 .L4_MAN_CAS BOOL Controller in CASCADE or MAN
665 0x0299 0xFD67 .L4_PID_D_OUT REAL D-portion of output signal
663 0x0297 0xFD69 .L4_PID_I_OUT REAL I-portion of output signal
1958 0x07A6 0xF85A .L4_PID_PS BOOL Change-over parameter set 1<->2
891 0x037B 0xFC85 .L4_PID_Y_OUT REAL Cont. output signal
721 0x02D1 0xFD2F .L4_R1 REAL Free REAL variable
723 0x02D3 0xFD2D .L4_R2 REAL Free REAL variable
725 0x02D5 0xFD2B .L4_R3 REAL Free REAL variable
727 0x02D7 0xFD29 .L4_R4 REAL Free REAL variable
729 0x02D9 0xFD27 .L4_R5 REAL Free REAL variable
731 0x02DB 0xFD25 .L4_R6 REAL Free REAL variable
733 0x02DD 0xFD23 .L4_R7 REAL Free REAL variable
735 0x02DF 0xFD21 .L4_R8 REAL Free REAL variable
1946 0x079A 0xF866 .L4_REGLER_AUTO BOOL Controller AUTO
1948 0x079C 0xF864 .L4_REGLER_C BOOL Controller CASCADE
1947 0x079B 0xF865 .L4_REGLER_MAN BOOL Controller MAN
671 0x029F 0xFD61 .L4_SCAL_LO REAL Lower control loop scaling
673 0x02A1 0xFD5F .L4_SCAL_HI REAL Upper control loop scaling
1964 0x07AC 0xF854 .L4_SETZ_AUTO BOOL Change-over to automatic mode
1965 0x07AD 0xF853 .L4_SETZ_CASC BOOL Change-over to cascade mode