- 18 -
000400BG
2 - Characteristics
Tightening torques
To maintain the IP65 protection of the system and for optimal installa-
tion, the following tightening torques must be used:
AC cable gland
19
M25 (ring nut xing)
5.0 Nm
AC cable gland
19
M25 (locknut xing)
7.5 Nm
Service cable glands
20
M20 (ring nut xing)
2.5 Nm
Service cable glands
20
M20 (locknut xing)
7.0 Nm
Front cover
05
1.5 Nm
AC output terminal block
10
- 16 mm
2
Max
1.5 Nm
Signal terminal block
13
- 1.5 mm
2
Max
0.25 Nm
O
verall dimensions
The overall dimensions are expressed in millimetres and inches and in-
clude the wall installation bracket
325 mm
12.8”
238.5 mm
9.4”
618 mm
24.3”