1- Introduction and safety
labels af¿xed to the equipment.
The nameplate shown is af¿xed
5. Certi¿cation
UL 1741
CSA-C22.2 No. 107.1-01
C US
®
Country of Origin Italy
www.abb.com/solar
SOLAR UTILITY INTERACTIVE
TRANSFORMERLESS INVERTER
MODEL:PVI-5000-OUTD-US
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following twoconditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received,including interference that
may cause undesidered operation.
For more details about product speci cations refer to the Instruction Manual
(
1
):
2
Adjustable from 57.0 Hz to 59.8 Hz
Adjustable from 60.2 Hz to 63.0 Hz
Nominal Input Operating Voltage
Max.Input Voltage
Range of Input Operating Voltage
Range of Input Voltage @Full Power
Max.Input Current
Max.Input Short Circuit Current (P.V.Panels)
DC RATING
Nominal Output Voltage
Operating Voltage Range
Nominal Output Frequency
Operating Frequency Range
Output Power Factor
Max.Output Current
AC RATING
Max. Continuous Output Power
Max. Output Overcurrent Protection
2 x 18A
2 x 22A
360V
600V
90 - 580 V
200 - 530V
60 Hz (factory preset)
59.3 ( ) - 60.5 ( ) Hz
1 2
>0.995
20 A / 23A / 27A (rms)
277V~ / 240 V~ / 208V~ 1Ø
25 A / 30 A / 35A
5000 W @ 60°C amb.
244-304 V~/211-264 V~/183-228 V~
DC Ground Fault Detector/Interrupter is Provided
Operating Ambient Temperature: -25 to +60 °C(-13 to +140 °F),with Output Power Derating
Typeof Enclosure:NEMA 4X
( ):
7
6
8
1
2
3
4
5