25. Ordering for pre-congured IED
GUID-44AC94A2-C927-463B-BB10-F4C476745D03 v11
Guidelines
Carefully read and follow the set of rules to ensure problem-free order management.
Please refer to the available functions table for included application functions.
PCM600 can be used to make changes and/or additions to the delivered factory configuration of the pre-configured.
To obtain the complete ordering code, please combine code from the tables, as given in the example below.
Example code: REG670 *2.2-A20X00- A02H39-B1X0-AA-CA-B-A12X0-CB1AL1XXXXXXXX-KKKXXHKKLAGXSY. Using the code of each position #1-11 specified as
REG670*1-2 2-3 3-4 4-5 6-7 7-8-9 9 9-10 10 10 10-11 11 11 11 11 11 11 11 11 11 11
# 1 - 2 - 3 - 4 - 5 6 - 7 - 8 - 9 -
REG670* 2.2 - - - - - - - -
10 - 11
-
Position
SOFTWARE #1 Notes and rules
Version number
Version no.
2.2
Selection for position #1
Conguration alternatives Ordering no #2 Notes and rules
Generator differential and back-up 1MRK004007-AG A20
Generator differential and generator/transformer back-up 1MRK004007-BG B30
Generator/transformer differential and back-up 1MRK004007-CG C30
ACT configuration
ABB standard configuration X00
Selection for
position #2
Software options Ordering no #3 Notes and rules
No option X00 All fields in the ordering form do
not need to be filled in.
Restricted earth fault protection, low impedance 1MRK004001-AA A01 A01 only for B30
High impedance differential protection - 3 blocks 1MRK004001-AB A02 A02 only for A20
Transformer differential protection - 2 winding 1MRK004001-AP A31 A31 only for A20
Transformer differential protection - 2 and 3 winding 1MRK004001-AR A33 A33 only for B30
Out-of-step protection 1MRK004001-BW B22
Rotor Fault Detection by Injection 1MRK004001-BV B31
Stator Fault Detection by Injection 1MRK004001-BX B32
Sensitive directional residual overcurrent and power protection 1MRK004001-CT C16
Voltage restrained overcurrent protection 1MRK004001-UN C36
Rotor overload protection 1MRK004001-UR C38
Four step directional negative phase sequence overcurrent protection - 1 block 1MRK004001-UH C41 C41 only for A20
Four step directional negative phase sequence overcurrent protection - 2 blocks 1MRK004001-UK C42 C42 only for B30/C30
100% Stator E/F 3rd harmonic 1MRK004001-DE D21 D21 only for A20
Frequency time accumulation protection 1MRK004001-EC E03
Fuse failure supervision based on voltage difference 1MRK004001-HC G03
Control functionality for up to 30 objects 1MRK004001-GZ H39
Transformer insulation loss of life monitoring 1MRK004001-KM M21 M21 only for B30/C30
IEC 62439-3 Parallel redundancy protocol 1MRK004001-PP P23 Options P23 and P24 require two
SFPs placed in pairs.
IEC 62439-3 High-availability seamless redundancy 1MRK004001-PR P24
IEC 61850-9-2 Process Bus communication, 8 merging units 1MRK004001-PT P30
Synchrophasor report, 16 phasors 1MRK004001-PX P34
Selection for
position #3
1MRK 502 074-BEN A
Generator protection REG670 2.2 and Injection equipment REX060,
REX061, REX062
Product version: 2.2.1
134 ABB