ABB REF611 User Manual

ABB REF611
188 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Relion
®
611 series
Feeder Protection and Control
REF611
Application Manual

Table of Contents

Other manuals for ABB REF611

Question and Answer IconNeed help?

Do you have a question about the ABB REF611 and is the answer not in the manual?

ABB REF611 Specifications

General IconGeneral
Product TypeFeeder Protection Relay
TypeREF611
Current Input1 A / 5 A
Frequency50/60 Hz
Binary Inputs8
Binary Outputs6
Protection FunctionsOvercurrent, Earth Fault, Thermal Overload, Circuit Breaker Failure
Overcurrent ProtectionYes
Earth Fault ProtectionYes
Thermal Overload ProtectionYes
Circuit Breaker Failure ProtectionYes
DisplayLCD
Communication ProtocolsModbus
CommunicationEthernet
MountingDIN rail mounting
Protection DegreeIP54

Summary

Section 1 Introduction REF611 Application Manual

This Manual

Describes the purpose and use of the application manual for protection functions and settings.

Intended Audience

Targets protection and control engineers with electrical power engineering experience.

Product Documentation

Outlines the set of manuals and related documentation for the REF611 series.

Symbols and Conventions

Explains warning symbols, icons, and document conventions used throughout the manual.

Section 2 REF611 Overview

Overview

Introduces the REF611 relay as a dedicated feeder protection device and its features.

Physical Hardware

Describes the relay's construction into plug-in unit and case.

Local HMI

Details the Local Human-Machine Interface, including display, LEDs, and keypad.

Web HMI

Explains access and functions via the Web Human-Machine Interface.

Communication

Covers supported communication protocols like IEC 61850 and Modbus.

Section 3 REF611 Standardized Configurations

Standardized Configurations

Presents the three alternative configurations (A, B, C) available for the REF611 relay.

Connection Diagrams

Provides visual diagrams showing physical connections for configurations A, B, and C.

Configuration A

Details the applications and functionality overview for Configuration A.

Configuration B

Details the applications and functionality overview for Configuration B.

Configuration C

Details the applications and functionality overview for Configuration C.

Section 5 Protection Relay's Physical Connections

Inputs

Describes the various input terminals for phase currents, residual current, voltage, and binary inputs.

Outputs

Details the output contacts for tripping, controlling, and signalling purposes.

IRF

Explains the IRF contact as an output for the self-supervision system.

Section 6 Glossary

611 Series

Series of relays for low-end protection and supervision applications.

IED

Intelligent electronic device for protection and control relay.

LHMI

Local human-machine interface for device interaction.

PCM600

Protection and Control IED Manager software.

WHMI

Web human-machine interface for remote access.