Software options Ordering no #3 Notes and rules
No option X00
1)
High impedance differential protection - 3 blocks 1MRK004001-AB A02
Line differential protection 6 CT sets 1MRK004001-AD A04
2)
,
3)
Line differential protection 6 CT sets + transformer 1MRK004001-AF A06
Line differential protection for 3 CT sets, 2-3 line ends 1MRK004001-AU A34
Sensitive line differential protection 4 CT sets 1MRK004001-AZ A35
Phase segregated scheme communication 1MRK004001-BE B05
High speed distance protection, quad and mho characteristic 1MRK004001-XA B35
4)
Out-of-step protection 1MRK004001-BW B22
5)
Pole slip protection 1MRK004001-VU B24
6)
Stub protection 1MRK004001-VK B27
7)
Sensitive directional residual overcurrent and power protection 1MRK004001-CT C16
Scheme communication for residual overcurrent protection 1MRK004001-VN C34
8)
Directional power and voltage restrained overcurrent protection 1MRK004001-VL C35
Average power transient earth fault protection 1MRK004001-UY C54
Overexcitation protection - 2 winding 1MRK004001-DC D03
Frequency protection - line 1MRK004001-ED E04
9)
General current and voltage protection 1MRK004001-FA F01
Fuse failure supervision based on voltage difference 1MRK004001-HC G03
Autorecloser, 1 circuit breaker 1MRK004001-GD H04
10)
Autorecloser, 2 circuit breakers 1MRK004001-GE H05
11)
Control functionality for up to 10 objects 1MRK004001-GW H37
12)
Control functionality for up to 15 objects 1MRK004001-GY H38
Through fault monitoring 1MRK004001-KR M22
Harmonic monitoring 1MRK004001-KS M23
IEC 62439-3 Parallel redundancy protocol 1MRK004001-PP P23
13)
IEC 62439-3 High-availability seamless redundancy 1MRK004001-PR P24
IEC 61850-9-2 Process Bus communication, 8 merging units 1MRK004001-PT P30
Synchrophasor report, 8 phasors 1MRK004001-PV P32
14)
Selection for
position #3
1) All fields in the ordering form do not need to be filled in.
2) Only one Line differential protection has to be selected.
3) A04, A06 and A34 only for B33
4) Only for B33/A42/B42
5) Only for B33/A42/ B42
6) Only for C42
7) Only for B33/B42; 1 block included as basic
8) Only for B33/A42/B42
9) 1 block already included
10) Only for A42/C42, 1 block already included
11) Only for B33/B42, 2 blocks already included
12) H37 only for A42/C42, H38 only for B33/B42
13) Options P23 and P24 require two SFPs placed in pairs.
14) This functionality requires accurate time synchronization, therefore either Precision Time Protocol (PTP) Time synch or GTM or IRIG-B will be required.
Language Ordering no #4 Notes and rules
First local HMI user dialogue language
HMI language, English IEC 1MRK002930-AA B1
Additional local HMI user dialogue language
No additional HMI language X0
HMI language, English US 1MRK002920-UB A12
1)
Selection for
position #4
B1
1) Additional 2nd languages are continuously being added. Please get in touch with local ABB sales contact.
Line differential protection RED670
1MRK 505 379-BEN N
Version 2.2
172 Hitachi Power Grids