CONDITION MONITORING
AND SUPERVISION
OR
AND
CONTROL AND INDICATION
1)
MEASUREMENT
CAPACITOR BANK PROTECTION AND CONTROL RELAY
STANDARD
CONFIGURATION
PROTECTION
LOCAL HMI
Object Ctrl
2)
Ind
3)
CB
DC
ES
1)
Check availability of binary inputs/outputs
from technical documentation
2)
Control and indication function for
primary object
3)
Status indication function for
primary object
R
L
ClearESC
I
O
Configuration A
System
HMI
Time
Authorization
R
L
ClearESC
I
O
U12 0. 0 kV
P 0.00 kW
Q 0.00 kVAr
IL2 0 A
A
REMARKS
Optional
function
No. of
instances
Alternative
function to be
defined when
ordering
OR
Io/Uo
Calculated
value
REV615
B
COMMUNICATION
P
rotocols:
IEC 61850-8-1/-9-2LE
Modbus
®
IEC 60870-5-103
DNP3
Interfaces:
Ethernet: TX (RJ45), FX (LC)
Serial: Serial glass fiber (ST),
RS-485, RS-232
Redundant p
rotocols:
HSR
PRP
RSTP
- I, U, Io, Uo, P, Q, E, pf, f
- Limit value supervision
- Load profile record
- RTD/mA measurement (optional)
- Symmetrical components
7
5
Analog interface types
1)
Current transformer
Voltage transformer
1)
Conventional transformer inputs
1 -
2 3
1 2
ALSO AVAILABLE
- Disturbance and fault
recorders
- Event log and
recorded data
- High-Speed Output module (optional)
- Local/Remote push button on LHMI
- Self-supervision
-
Time synchronization: IEEE 1588 v2,
SNTP, IRIG-B
- User management
-
Web HMI
Master Trip
Lockout relay
94/86
PQM3I
PQM3I
TCS
TCM
MCS 3I
MCS 3I
CBCM
CBCM
OPTS
OPTM
MAP
MAP
2x
R
TD
1xmA
Io>>
51N-2
Io>
67N-1
Io>>
67N-2
3U<
27
U2>
47O-
U1<
47U+
3U>
59
Uo>
59G
FUSEF
60
I2>
46
3I>>>
50P/51P
ARC
50L/50NL
3I>/Io>BF
51BF/51NBF
3I>
51P-1
3I>>
51P-2
TD>
55TD
3I>3I<
51C
3dI>C
51NC-2
dI>C
51NC-1
PQM3U
PQM3V
PQMU
PQMV
Uo>
59G
3Ith>T/G/C
49T/G/C
3I
3I
Io
Io
Io
Iunb
Io>IEF
67NIEF
U
L1
U
L2
U
L3
U
L1
U
L2
U
L3
U
L1
U
L2
U
L3
Uo
Uo
Uo
Master Trip
Lockout relay
94/86
PQUUB
PQVUB
GUID-393D9B25-06C8-42AE-A7D0-642BBCB89DBE V2 EN
Figure 2. Functionality overview for standard configuration B
Table 1. Standard configurations
Description
Std. conf.
Capacitor bank overload and unbalance protection, non-directional overcurrent and earth-fault protection and circuit-breaker
condition monitoring
A
Capacitor bank overload and unbalance protection, non-directional overcurrent and directional earth-fault protection, voltage and
frequency based protection and measurements, and circuit-breaker condition monitoring
B
Capacitor Bank Protection and Control
1MRS757952 D
REV615
Product version: 5.0 FP1
ABB 5

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB REV615 and is the answer not in the manual?

ABB REV615 Specifications

General IconGeneral
BrandABB
ModelREV615
CategoryPower distribution unit
LanguageEnglish

Related product manuals