Electrical connection
24 RHD250 ... 4000 42/68-165-EN
Pos: 10.1 /Überschri ften/1/D - F/Elektri scher Anschluss @ 0\mod_1140 620471687_3101.doc @ 3143
4 Electrical connection
Pos: 10.2 /Elektri scher Anschluss/Aktor ik/Antriebe/Al lgemein/Elektrisc her Anschluss RHD @ 16\mod_1197 274093609_3101.doc @ 145053
Each actuator requires a Contrac electronic unit which is loaded with the type specific-software.
Carefully consider the instructions for the electronic unit and compare the data labels of the
actuator and the electronic unit in order to ensure a proper hard- and software assignment.
Pos: 10.3 /Überschri ften/1.1/1-spa ltig/J - L/Kabelschir m @ 10\mod_1181823716656_3 101.doc @ 106187
4.1 Cable shield
Pos: 10.4 /Überschri ften/1.1.1/1-spal tig/Signalteil @ 10\ mod_1182501083765_31 01.doc @ 108573
4.1.1 Signal part
Pos: 10.5 /Elektri scher Anschluss/Aktor ik/Antriebe/Al lgemein/Kabelschi rm Anschluss @ 10\mod_11818 23021906_3101.doc @ 106144
3
3
4
2
2
1
1
M00307
Fig. 14: Fitting the shield
1. Remove approx. 2 cm of cable sheathing (3) from the end of the cable.
2. Separate the shield and peel it back to its inner sheathing (4).
3. Push the cable through the cable gland and fasten with clamp (1).
4. Make sure that the shielding is touching the clamp and the electronic unit housing (2).
Pos: 10.6 /====== = Seitenumbruch ======= = @ 0\mod_1126532365768_3101.doc @ 3830