Fitting the filter silencer
u Assemble the insert units (E) by inserting the absorption seg-
ments(81136) into the sheet-metal coverings(81137).
u Bend the sheet-metal coverings back into the original shape.
u Insert the insert units (E) into the slot guides in the filter silencer body
(81135).
NOTICE
If the cleaning medium vessel is attached to the filter silencer (option
depends on type of turbocharger), the water injection pipe must first
be removed at one insert unit (E) (see also the following section Disas-
sembling the cleaning pipe).
u Fit cover grids (81266) and connecting strips (81268) on the filter si-
lencer body (81135).
u Run tension bands (81270) through the eyelets of the connecting
strips.
u Tighten all tension bands at locks (81271).
If provided
u Fit filter ring(81265).