Operation Manual / TPS48-D/E.. - TPS61-D/E.. 
 
 
 
  Page 89
 
 
© Copyright 2016 ABB. All rights reserved.
 
September 2016 HZTL2410_EN Revision E 
7.3 
  Disconnect all exhaust gas and air lines according to the instructions 
of the enginebuilder. 
Version with water-cooled bearing casing: 
  Disconnect the water pipes according to the instructions of the en-
ginebuilder. 
 
If present, remove hard insulation as follows: 
  Remove screws and sheet metal (B) from the bearing casing insula-
tion. 
  Remove the remaining screws from the bearing casing insulation (A). 
  Pull the bearing casing insulation up and off. The bearing casing insu-
lation can be compressed to facilitate the removal process. 
 
  Unplug the cable connector from the speed sensor. 
  Attach lifting gear to bearing casing. 
  If a gas outlet bend is present, sling lifting gear around it or secure it to 
the lifting gear with a swivel lifting eye (C). 
  Loosen the fixing screws (D) on the bearing casing. 
  Lift the turbocharger from the engine and put it down. 
  Cover oil connections.