000692AG
5 - Installation
Communication and control signal connections to the UNO-DM-
COM KIT board (only for -X / -E version)
Each cable which must be connected to the UNO-DM-COM KIT or UNO-
DM-PLUS-COM Ethernet KIT board connectors must be passed through
the specic cable conduit present on the plastic shield of the mainboard,
then it must be passed through the service cable glands
20
present on
the lower side of the inverter. An M25 cable gland (that takes cables from
10 mm to 17 mm in diameter) and a gasket with two holes to insert into
the cable gland which enables two separate cables of a maximum dia-
meter of 6 mm to be accommodated, are available.
Warning! To ensure environmental protection IP65 it is necessary to x the cable glands to
the inverter chassis with a minimum tightening torque of 7.5 Nm
The connection of the wires to the terminals is performed as
follows:
1.
Press and hold the button corresponding to the terminal
where the wire is to be connected
2.
Insert the cable
3.
Release the button
4.
Pull the wire to check the tightness.