5.5.5. Types of withdrawable circuit-breakers available for PowerCube modules
Ur Isc Rated uninterrupted current (40°C) [A] Circuit-breaker type
kV kA W=650 W=800 W=1000 W=1000 W=1000
P=150 P=210 P=275 P=275 P=275
u/l=205 u/l=310 u/l=310 u/l=310 u/l=310
ø=35 ø=79 ø=79 ø=109 ø=109
16 630 VD4/P 12.06.16 p150
20 630 VD4/P 12.06.20 p150
25 630 VD4/P 12.06.25 p150
31.5 630 VD4/P 12.06.32 p150
16 1250 VD4/P 12.12.16 p150
20 1250 VD4/P 12.12.20 p150
25 1250 VD4/P 12.12.25 p150
31.5 1250 VD4/P 12.12.32 p150
16 630 VD4/W 12.06.16 p210
20 630 VD4/W 12.06.20 p210
25 630 VD4/W 12.06.25 p210
31.5 630 VD4/W 12.06.32 p210
16 1250 VD4/W 12.12.16 p210
20 1250 VD4/W 12.12.20 p210
25 1250 VD4/W 12.12.25 p210
31.5 1250 VD4/W 12.12.32 p210
40 1250 VD4/P 12.12.40 p210
20 1600 VD4/P 12.16.20 p210
25 1600 VD4/P 12.16.25 p210
31.5 1600 VD4/P 12.16.32 p210
40 1600 VD4/P 12.16.40 p210
20 2000 VD4/P 12.20.20 p210
25 2000 VD4/P 12.20.25 p210
31.5 2000 VD4/P 12.20.32 p210
40 2000 VD4/P 12.20.40 p210
20 2500 VD4/P 12.25.20 p275
25 2500 VD4/P 12.25.25 p275
31.5 2500 VD4/P 12.25.32 p275
40 2500 VD4/P 12.25.40 p275
20 3150 VD4/W 12.32.20 p275
25 3150 VD4/W 12.32.25 p275
31.5 3150 VD4/W 12.32.32 p275
40 3150 VD4/W 12.32.40 p275
16 630 VD4/P 17.06.16 p150
20 630 VD4/P 17.06.20 p150
25 630 VD4/P 17.06.25 p150
31.5 630 VD4/P 17.06.32 p150
16 1250 VD4/P 17.12.16 p150
20 1250 VD4/P 17.12.20 p150
25 1250 VD4/P 17.12.25 p150
31.5 1250 VD4/P 17.12.32 p150
16 630 VD4/W 17.06.16 p210
20 630 VD4/W 17.06.20 p210
25 630 VD4/W 17.06.25 p210
31.5 630 VD4/W 17.06.32 p210
16 1250 VD4/W 17.12.16 p210
20 1250 VD4/W 17.12.20 p210
25 1250 VD4/W 17.12.25 p210
31.5 1250 VD4/W 17.12.32 p210
40 1250 VD4/P 17.12.40 p210
20 1600 VD4/P 17.16.20 p210
25 1600 VD4/P 17.16.25 p210
31.5 1600 VD4/P 17.16.32 p210
40 1600 VD4/P 17.16.40 p210
20 2000 VD4/P 17.20.20 p210
25 2000 VD4/P 17.20.25 p210
31.5 2000 VD4/P 17.20.32 p210
40 2000 VD4/P 17.20.40 p210
20 2500 VD4/P 17.25.20 p275
25 2500 VD4/P 17.25.25 p275
31.5 2500 VD4/P 17.25.32 p275
40 2500 VD4/P 17.25.40 p275
20 3150 VD4/W 17.32.20 p275
25 3150 VD4/W 17.32.25 p275
31.5 3150 VD4/W 17.32.32 p275
40 3150 VD4/W 17.32.40 p275
17.5
Notes
W = Width of the switchgear.
P = Pole horizontal centre distance.
u/l = Distance between bottom and top terminal.