11. Spare parts and accessories
All assembly operations of spare parts/accessories must
be carried out following the instructions enclosed with
the spare parts, by ABB personnel or by suitably
qualified customer personnel with in-depth knowledge
of the apparatus (IEC 60694) and of all the Standards
aimed at carrying out these interventions in safe
conditions. Should the maintenance be carried out by
the customer’s personnel, responsibility for the
interventions remains with the customer. Before carrying
out any operation, always make sure that the circuit-
breaker is open, the spring discharged and that it is not
energised (medium voltage circuit and auxiliary circuits).
To order circuit-breaker spare parts/accessories, refer to the ordering
sales codes indicated in the technical catalogue and always state the
following:
type of circuit-breaker
rated voltage of the circuit-breaker
rated normal current of the circuit-breaker
breaking capacity of the circuit-breaker
serial number of the circuit-breaker
rated voltage of any electrical spare parts.
For availability and to order spare parts, please contact our Service
office.
11.1. List of spare parts
Shunt opening release
Additional shunt opening release
Undervoltage release
Contact for signalling undervoltage release energised/de-energised
Time delay device for undervoltage release
Mechanical override for undervoltage release
Shunt closing release
Spring charging geared motor with electrical signalling of spring
charged
Contact signalling protection circuit-breaker of the geared motor
open/closed
Contact signalling closing spring charged/discharged
Transient contact with momentary closing during circuit-breaker
opening
Circuit-breaker auxiliary contacts
Locking electromagnet on the operating mechanism
Position contact of the withdrawable truck
Contacts signalling connected/isolated
Opening solenoid
Key lock in open position
Isolation interlock with the door
Protection for opening pushbutton
Protection for closing pushbutton
Locking electromagnet on the withdrawable truck
Set of six tulip contacts.
12. Electric circuit diagrams
The standard VD4 circuit-breaker electric circuit diagrams are as
follows:
1VCD400046: Fixed circuit-breakers
1VCD400055: Fixed circuit-breakers with 64-pole connector
1VCD400064: Fixed circuit-breakers with 58-pole connector
1VCD400078: Fixed circuit-breakers with truck
1VCD400048: Withdrawable circuit-breakers
1VCD400080: Withdrawable circuit-breakers for ZS8.4 switchgear
VD4/ZS8, ZT8 and Z8 with circuit-breaker.
1VCD400080: Withdrawable circuit-breakers for ZS8.4 switchgear
with VD4/ZS8, ZT8 and Z8 circuit-breaker with motorized truck.
Each circuit-breaker is always provided with the standard electric
diagram or with a specific diagram in the case of a circuit-breaker with
non-standard cabling.