56 | XSERIES G5 START UP GUIDE | 2106001MNAA
Figure 10-2: TF Remote - COM 1
5. On the Protocol menu, select the appropriate protocol if not using
the default Totalflow Remote.
6. Under Serial Port Settings, on the Interface menu, select the
communication interface (RS-232, RS-485, or RS-232 Modem).
7. Verify, and change if necessary, the remaining serial port settings
and timeouts and delays.
Table 10-1: Communication setup parameters
Timeouts and delays
Serial port settings
Parameter
Default
Parameter
Default
Ack timeout (s)
15
Baud
9600
Response delay
(ms)
40
Parity
None
Xmit key delay
(ms)
420
Data bits
8
Unkey delay (ms)
40
Stop bits
1
Power up delay
(ms)
80