Micro Tracker Reference Guide FW 1.7 V1.1
Page 29 of 39
11th october 2018
Restricted distribution
5.5.6 BLE payload
Common header
Data
Byte 0-4
Byte
5
Byte
6-11
Byte
12
Byte
13-18
Byte
19
Byte
20-25
Byte
26
Byte
27-33
Byte
34
Header
Age
MAC ADR0
RSSI0
MAC ADR1
RSSI1
MAC ADR2
RSSI2
MAC ADR3
RSSI3
Age: encoded form of scan age with lo=0, hi=2040, nbits=8, nres=0. Expressed in seconds.
MAC ADRx: MAC Address of the BLE beacon x.
RSSIx: Receive Signal Strength Indication of the BLE beacon x. Non encoded form (signed 8 bits). It is
expressed in dBm.
Notes
1- The payload contains the listened BLE beacon (up to 4, it is configurable using ble_beacon_count
parameter ), during ble_beacon_timeout delay.
2- If less than 4 BLE beacons are listened, the payload will be reduced.
5.5.7 BLE failure payload
Common header
Data
Byte 0-4
Byte 5
Header
Error
Error:
0: BLE is not responding
1: internal error
2: shared antenna not available
3: scan already on going
4: No beacon detected
5: hardware incompatibility
5.6 Energy Status messages
This message should be used for the primary battery life estimation. It is not useful for micro tracker
5.7 Activity status messages
Common header
Data
Byte 0-4
Byte 5
Byte 6-9
Header
Tag=1
Activity