EasyManua.ls Logo

ABL SURSUM eMH1 Basic - Appendix; Specifications; Standards & Directives

ABL SURSUM eMH1 Basic
34 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix
23
Appendix
Specifications
MODEL VARIANT EVSE 563
Compliance IEC 61851-1/22
Rated voltage 230/400 V 50 Hz
Rated current 32 A (MCB required onsite)
Max. output 22 kW
Charging cable Type 2, length ca. 5 m
Circuit-protection devices external RCCB required onsite
Energy meter not included
Control/ Customization internal RS485 interface
Terminal block up to 6 mm
2
Operating temperature -25°C to 50°C
Storage temperature -30°C to 85°C
Relative humidity 5 to 95% (no condensation)
Class of protection I
Degree of protection (housing) IP54
Overvoltage category III
Dimensions 272 x 220 x 106 mm (H x W x D)
Weight per unit ca. 4.9 kg
Standards & directives
Your eMH1-EVSE 563 charging station complies with the following standards and
classes of protection:
General standards
STANDARD DESCRIPTION
2004/108/EC
EMC Guideline
2002/95/EC
RoHS Guideline
2002/96/EC
WEEE Guideline
ElektroG
Electrical and Electronic Device Statute

Related product manuals