8. ts_Set_ReverseRate (unsigned char revRate)
A. This function set the level for key reverse situation (rawdata>basedata+α) judgement.
B. Key reverse situation level is revRate % of threshold.
9. ts_Set_ReverseTime (unsigned char revTime)
A. This function set the reverse holding time (unit: ms).
B. After this time, rawdata and basedata are matched.
Figure 24. Reverse Situation Parameters