EasyManua.ls Logo

Abus SHBW10000 - Page 13

Abus SHBW10000
15 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13
English
102 4
Humidity report
Time
7200
The interval time of the humidity report.
The value 0 disables the report.
Adjustable from 0 - 2678400 in seconds
The value is always rounded up to the full
minute. (e.g. 62 seconds -> value is rounded up
to 120 seconds)
(Hexadecimal: 0x00 0x28DE80)
103 4
Brightness
report
Time
7200
The interval time of the brightness report.
The value 0 disables the report.
Adjustable from 0 - 2678400 in seconds
The value is always rounded up to the full
minute. (e.g. 62 seconds -> value is rounded up
to 120 seconds)
(Hexadecimal: 0x00 0x28DE80)
104 4
Battery report
Time
86400
The interval time of the battery report.
The value 0 disables the report.
Adjustable from 0 - 2678400 in seconds
The value is always rounded up to the full
minute. (e.g. 62 seconds -> value is rounded up
to 120 seconds)
(Hexadecimal: 0x00 0x28DE80)
110 1
Enable/Disable
Report 111-114
0
Enable or disable reports 111-114.
0 = Reports are disabled
1 = Reports are enabled
(Hexadecimal: 0x00 0x01)
111 2
Temperature
report
Threshold
10
The threshold value serves as an additional
condition for the time-based report.
If the threshold value was not exceeded, the
time-based report is not sent.
Adjustable from 1 - 500 in 0,1°.
(e.g. 25 = 2.5°)
(Hexadecimal: 0x01 0x1F4)
112 1
Humidity
report
Threshold
5
The threshold value serves as an additional
condition for the time-based report.
If the threshold value was not exceeded, the
time-based report is not sent.
Adjustable from 1 - 32 in percent
(Hexadecimal: 0x01 0x20)

Other manuals for Abus SHBW10000