Msg Min Def Max Detail
CLDN 30 60 180 Cool Down cycle in seconds. Whenever
the heater is turned off the pump keeps
running the extra seconds to even the
temperature of the heater element and
the surrounding water to prevent scale
build up and premature heater failure.
ECL 60 180 240 Economy Cycle Length. Time in minutes
to specify the intervals between spa
temperature sampling when the spa is
not in use. During this period the spa is
in economy mode. Temperature is
sampled at the end of the period. Press
any key to cancel this mode.
CHCL 0 60 180 Channel Clear. Time in seconds to clear
the air channel and the secondary
pump(s) plumbing if the spa has not
been used for a period of 24 hours. This
prevents water stagnation in the
plumbing.
UTO 10 20 60 User Time Out. The time in minutes from
starting any device, after which all
devices will be turned off, and the spa
put in not in use mode. If you should
leave the spa with a pump or light
running, it will be turned off after the
specified time.
PUF 60 120 180 Post Use Filtration. Time in minutes to
perform Post Use Filtration this is the
optimal time to filter the spa. When you
have finished using the spa, that is when
it needs filtration the most. Press the
SET key to turn everything off and start
this cycle. This cycle is performed only
once and after pressing the SET key. It is
in addition to the standard filtration
cycles. Pressing any other device key
will cancel this function.