Page 13
PAR AMETER MENU LIST
Press momentarily the “SET” & “DOWN ARROW” keys at the
same time to access the following options.
Msg Min Def Max Detail
FP1 12:00 Start time of filtration period 1
FP2 12:00 Start time of filtration period 2
FP3 12:00 Start time of filtration period 3
FP4 12:00 Start time of filtration period 4
Note : If filtration periods overlap,
the most recent period (last) is in
the effect.
SIL 12:00 Start time of the silence period.
This is a period which nothing will
run. It overrides all filtrations, the
economy cycle, and temperature
sampling. Except if temperature
drops below 40 degrees. A spa may
be installed near a bedroom and
need not come on at specific times.
FP1d 0 0 240 Duration in minutes FP1 timer will run.
FP2d 0 0 240 Duration in minutes FP2 timer will run.
FP3d 0 0 240 Duration in minutes FP3 timer will run.
FP4d 0 0 240 Duration in minutes FP4 timer will run.
SILd 0 0 12 Duration in hours the Silence Timer
runs. Only a user may override the
silence timer.
Note : Keep the value of any time to 0 to keep it from
running. Filtration timers must be programmed first
one first. If the FP1d (first) timer has a duration of 0,
Auto Filtration will be in effect and all 4 programmed
timers will be disabled.