Accuphase Laboratory Inc.
Issued 2005-7-6
No. A-60-001
MODEL : A-60
SUBJECT : The measure at the time of decrease voltage
減電圧の対策
Details ;To prevent becoming instability of operation by the bridge
connection and the balance input connection at the time of
decrease voltage,the measures is performed as follows.
Measure : Logic Ass'y/capacitor C2: 470uF→1,000uF
; ブリッジ接続、バランス入接続にて電圧時に作不安定となのを防止
する。
対策 ;ロジックAss'y、コンデンサC2 :470uF→1,000uF 変更しま
Service Information
To be changed as follows
.
Electrolytic Capacitor
アルミ解コンデンサ
25V/470uF→16V/1000uF
(CE04W1E471→CE04W1C102)
C2
Logic Assembly/ロジックAss'y
(721-0077-00)
TOP VIEW/ BOTTOM VIEW/
An applicable serial number is as follows.
/
該当シリアル番号は次の通
E4Y001~100, F4Y101~200, L4Y201~300.
Electrolytic Capacitor CE04W1C102 1pce. C2: 1,000uF/16V
電解コンデンサ
C2