Do you have a question about the Accuphase A-60 and is the answer not in the manual?
stereo power at 1 ohm | 480 watts per channel |
---|---|
stereo power at 2 ohms | 240 watts per channel |
stereo power at 4 ohms | 120 watts per channel |
stereo power at 8 ohms | 60 watts per channel |
monophonic power at 2 ohms | 960 watts |
monophonic power at 4 ohms | 480 watts |
monophonic power at 8 ohms | 240 watts |
stereo operation distortion at 2 ohms | 0.07 % |
---|---|
stereo operation distortion at 4 to 16 ohms | 0.05 % |
monophonic operation distortion at 4 to 16 ohms | 0.03 % |
rated output frequency response | 20 - 20, 000 Hz +0, -0.2 dB |
---|---|
1 watt output frequency response | 0.5 - 160, 000 Hz +0, -3.0 dB |
max gain | 28.0 dB |
---|---|
-3 dB gain | 25 dB |
-6 dB gain | 22 dB |
-12 dB gain | 16 dB |
AC voltage | 120 V / 230 V, 50 / 60 Hz |
---|---|
power consumption idle | 300 watts |
power consumption IEC-65 | 550 watts |
width | 465 mm |
---|---|
height | 238 mm |
depth | 545 mm |
weight net | 45.1 kg |
weight in shipping carton | 54.0 kg |
Safety instructions for qualified personnel to reduce electric shock risk.
Mark indicates safety-critical parts requiring identical replacement parts.
Adjusting bias current for left and right channels of the power amplifier.
Procedure for verifying and adjusting meter readings for output voltage.
Steps for changing the AC line voltage, including wiring and component selection.
Table detailing voltage settings, assembly numbers, and required parts.
Details on preventing instability due to voltage decrease by changing a capacitor.
Detailed circuit diagram for the power amplifier assembly.
Detailed circuit diagram for the protection assembly.