- 38 -
XGA
1024x768@60Hz
1344x806
48.363
60.004
65.000
1024x768@70Hz
1328x806
56.476
70.069
75.000
1024x768@75Hz
1312x800
60.023
75.029
78.750
MAC
1152x870@75Hz
1456x915
68.681
75.062
100.000
VESA
1152x864@75Hz
1600x900
67.5
75
108
1280x960@60Hz
1800x1000
60
60
108
SXGA
1280x1024@60Hz
1688x1066
63.981
60.020
108.000
1280x1024@75Hz
1688x1066
79.976
75.025
135.000
Note:
1. Show “Input Not Supported” warning message.
When Vertical Frequency is over 76Hz or under 56Hz, the display is Black and showing “Input Not
Supported” warning message. (Some video timings are except for PAL, 50Hz signals.)
2. If Hf /Vf is set in the range of 31KHz~83KHz and 56Hz ~76Hz (not including some video timing), and
Pixel Clock is set in the range of 25.175MHz~173MHz(DVI and HDMI input port 165MHz for Single-
Link), but is not the above Resolution, then it will display the nearest mode.
5.1.3 ADC calibration (Auto color balance adjustment)
~~Analog only, it is not required for DVI-D input source
1. Setup input timing ICL-605( 1280x1024@75Hz ), pattern 42(5-Mosaic pattern with white color block)
with Analog signals from Chroma video pattern generator. (it depends on Scaler IC suppliers recommendation)
2. Enter factory mode (press “Empowering” & “Power” buttons at the same time to turn on monitor).
3. Move cursor into “Burn-in Mode” tag and select “On” to enable burn-in mode.
4. Close OSD menu then press “Auto” button for auto color adjustment. (This procedure will get optimal
gain/offset(clamp) values)
5. Checking if the picture is ok, or reject this monitor and check its circuit board or wire/cable connection.
5.1.4 Color temperature adjustment
1. Setup input timing to any preset modes, pattern 41(full white color pattern) with Analog signals from
Chroma video pattern generator.
2. Enter factory mode (press “Empowering” & “Power” buttons at the same time to turn on monitor).
3. Move cursor into “Burn-in Mode” tag and select “On” to enable burn-in mode.
4. Make sure ADC calibration (auto color balance adjustment) had already been done.
5. Measure color temperature by Minolta CA-110 (or equivalent equipment).